The efficacy of a novel zinc-containing desensitizer CAREDYNE Shield on dentin hypersensitivity: study protocol for a pilot randomized controlled trial

Abstract: Background: Dentin hypersensitivity (DH) is a condition characterized by short and sharp pain which will arise in response to tactile, chemical, thermal, evaporative or osmotic stimuli. The painful symptoms cause discomfort to the patients and decrease their quality of life. Recently, a novel zinc-containing desensitizer CAREDYNE Shield is developed. It is a new type of desensitizer which acts as a desensitizer by inducing chemical occlusion of dentinal tubules, and releases zinc ion for root caries prevention… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 13 publications
0
1
0
Order By: Relevance
“…Although the SS group exhibited nearly the same failure mode as that in the Cont(#4000), it is not currently known why the bond strength was lower. In the CS group, it is thought that deposited calcium fluoride or calcium phosphate or released zinc ions [24][25][26][27] may have suppressed the etching effect of the acidic monomer of the bonding resin 26) , thereby decreasing the bonding strength, demonstrating the failure at the interface between the dentin and the bonding resin. However, the NS group exhibited nearly the same bond strength and failure mode (cohesive failure inside the bonding resin, cohesive failure inside the resin and cohesive failure inside the dentin) as in the Cont(#4000) group, and the interfacial failure was found in some specimens.…”
Section: Bond Strength Immediately After Application and 7 Days Latermentioning
confidence: 99%
“…Although the SS group exhibited nearly the same failure mode as that in the Cont(#4000), it is not currently known why the bond strength was lower. In the CS group, it is thought that deposited calcium fluoride or calcium phosphate or released zinc ions [24][25][26][27] may have suppressed the etching effect of the acidic monomer of the bonding resin 26) , thereby decreasing the bonding strength, demonstrating the failure at the interface between the dentin and the bonding resin. However, the NS group exhibited nearly the same bond strength and failure mode (cohesive failure inside the bonding resin, cohesive failure inside the resin and cohesive failure inside the dentin) as in the Cont(#4000) group, and the interfacial failure was found in some specimens.…”
Section: Bond Strength Immediately After Application and 7 Days Latermentioning
confidence: 99%