The efficient workflow to decrease the manual microscopic examination of urine sediment using on-screen review of images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 18 publications
0
10
0
1
Order By: Relevance
“…The automation of the diagnostic process has contributed to lower labor costs and inter-observer variability. 15 The NMP22 test was introduced for detection of a nuclear mitotic apparatus protein elevated in bladder cancer. 16,17 In newly diagnosed or recurrent TCC, the sensitivity and specificity of assay ranged from 33%-98% and 40%-92%, respectively.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The automation of the diagnostic process has contributed to lower labor costs and inter-observer variability. 15 The NMP22 test was introduced for detection of a nuclear mitotic apparatus protein elevated in bladder cancer. 16,17 In newly diagnosed or recurrent TCC, the sensitivity and specificity of assay ranged from 33%-98% and 40%-92%, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Fully automated platforms based on the imaging analysis have also improved diagnosis over traditional manual procedures. The automation of the diagnostic process has contributed to lower labor costs and inter‐observer variability 15 . The NMP22 test was introduced for detection of a nuclear mitotic apparatus protein elevated in bladder cancer 16,17 .…”
Section: Discussionmentioning
confidence: 99%
“…Sysmex UF‐1000i (TOA Medical Electronics, Kobe, Japan) flow cytometer makes urine particle counting more precise and effective. Several guidelines recommended that negative results of WBC or RBC from urine strips can be reported without checking by manual microscopy, and optimizing workflow also helps to decrease the microscopic examination of the samples with positive results of urine strips . A few laboratories have amended their own criterions and make them suitable for joint detection of urine flow cytometer and urine dipstick to reduce manual urine microscopy analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Routine urinalysis is frequently performed to help diagnosis and monitor urine tract and kidney diseases. Automated urinalysis flow cytometer such as Sysmex UF series has been adopted in clinical laboratory for almost two decades . When reporting the cell counts, the UF‐1000i system provides two different kinds of units, which are “cells per μL (non‐centrifugal urine)” and “cells per HPF (by calculated automatically).” The value of UF series is obviously higher than those obtained with microscopic examination, which brings confusion to clinicians when they are not used to the units of UF series …”
Section: Introductionmentioning
confidence: 99%
“…Moreover, more detailed analyzers use digital-image-based systems, including most mainstream manufacturers, such as Roche, Siemens, and Beckman. [4,6]. However, this method still fails to completely solve the low sensitivity of urine cytology [7].…”
Section: Introductionmentioning
confidence: 99%