Asynchronized (doubly-fed) machines with two (three) excitating winding and reversing excitation system allow to control vector of magnetomotive force. This solution allows separating regulation of the electromagnetic torque (active power) and voltage (reactive power). This paper describes the experience in the development and operation of asynchronized turbogenerators and condensers.