Abstract: A variety of amino acids were enantioresolved on a vancomycin bonded chiral phase using the polar-organic mobile phases after their pre-column derivatization with electrophilic reagents in alkaline medium. The resolution was highly dependent on the analyte's structure and was enhanced as the aromatic side-chain group on the skeleton of analyte for pi-pi interaction with the chiral selector became available. The steric hindrance resulting from the bulky side-chain group on the analyte also affected the resoluti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 13 publications
0
4
0
Order By: Relevance
“…The elution order of the separated amino acid enantiomeric peaks appeared to be varied on Chiralcel OD and Chiralcel OJ columns, suggesting the use of the two chiral columns in a complimentary manner (Lee et al, 2008). Chen (2005) made observations of elution order switches when amino acids were resolved on vancomycin bonded chiral phases after the analytes were subjected to pre-column derivatization with electrophilic reagents. Elution reversal was readily observed when the derivatization reagent was changed from 2,4-difluorophenylisocyanate to 2,4-difluorophenylisothiocyange (Chen, 2005).…”
Section: Reversal In Elution Order In Liquid Chromatography-compilatimentioning
confidence: 96%
See 2 more Smart Citations
“…The elution order of the separated amino acid enantiomeric peaks appeared to be varied on Chiralcel OD and Chiralcel OJ columns, suggesting the use of the two chiral columns in a complimentary manner (Lee et al, 2008). Chen (2005) made observations of elution order switches when amino acids were resolved on vancomycin bonded chiral phases after the analytes were subjected to pre-column derivatization with electrophilic reagents. Elution reversal was readily observed when the derivatization reagent was changed from 2,4-difluorophenylisocyanate to 2,4-difluorophenylisothiocyange (Chen, 2005).…”
Section: Reversal In Elution Order In Liquid Chromatography-compilatimentioning
confidence: 96%
“…Elution reversal was readily observed when the derivatization reagent was changed from 2,4-difluorophenylisocyanate to 2,4-difluorophenylisothiocyange (Chen, 2005). It was attributed to the bulkiness produced by the sulfur atoms in the reagent which resulted in steric hindrance phenomenom leading to reversal in elution order (Chen, 2005).…”
Section: Reversal In Elution Order In Liquid Chromatography-compilatimentioning
confidence: 97%
See 1 more Smart Citation
“…Analytes were detected at 260 and 270 nm. It was concluded from the results that amino acid enantiomers can be readily resolved under the experimental conditions outlined above and the structure of analyte exerts a considerable influence on the separation of enantiomers (Chen, 2005).…”
Section: Chiral Separations By Hplcmentioning
confidence: 99%