2011
DOI: 10.1016/j.buildenv.2010.09.015
|View full text |Cite
|
Sign up to set email alerts
|

The fluid mechanics of the natural ventilation of a narrow-cavity double-skin facade

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
5

Year Published

2012
2012
2018
2018

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 65 publications
(34 citation statements)
references
References 27 publications
0
28
0
5
Order By: Relevance
“…It should be noted that although the latter is the only case in which numerical results prove a worse situation cooling-wise, there are agreed and well-argued concerns about overheating issues within the studies reviewed here [6,12,60,80,84,85]. Such a phenomenon also highlights summer indoor comfort issues related to DSFs.…”
Section: Dsf Heating Loads Reduction Potentialmentioning
confidence: 70%
“…It should be noted that although the latter is the only case in which numerical results prove a worse situation cooling-wise, there are agreed and well-argued concerns about overheating issues within the studies reviewed here [6,12,60,80,84,85]. Such a phenomenon also highlights summer indoor comfort issues related to DSFs.…”
Section: Dsf Heating Loads Reduction Potentialmentioning
confidence: 70%
“…Antibacterial properties (resistance to rot) and chemical resistance allows the use of polystyrene in a corrosive environment. [14,26] In current practice as insulation material in the territory of Russia are widespread mineral wool based on basalt binder, as well as boards based on expanded polystyrene. In some parts of the building, such as caps and place of constant accumulation and retention of water used slabs of polystyrene, obtained by extrusion.…”
Section: Types Of Mineral Woolmentioning
confidence: 99%
“…Gratia [27] explains that double-skin facades are derived progressively from the concept of a faç ade deigned entirely by glass. On the other hand, referring to the study by Mingotti et al [28], the external and internal layers of DSFs must have versatile openings in order to ensure air ventilation within the cavity as well as the interior atmosphere of the adjacent interior spaces. In view of that, it is reflected that the temperature and air ventilation are inherently related to the size of cavity, hence, the studies by Balocco and Colombari [29], Balocco [30] confirm that once the widths of cavity gets decreased, there is a high risk of being confronted with an overheating faç ade layer particularly, in summer.…”
Section: The Relationship Between Double Skin Façadementioning
confidence: 99%