The Freedom Solo pericardial stentless valve: Single-center experience, outcomes, and long-term durability

Abstract: The Freedom Solo stentless aortic valve is safe to implant and shows excellent early and midterm hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5-6 years and the need for explantation increased markedly, suggesting low durability.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 33 publications
0
6
0
Order By: Relevance
“…Relative to stented valves, such valves offer the advantage of combining a non‐obstructive effective orifice area (EOA) with a flexible aortic root that is thought to be essential for natural leaflet stress distribution, thereby limiting valve degeneration and failure . Depending on prosthesis size, the EOA increases two‐ to threefold after FS implantation and has been reported (mean ± standard deviation [SD]) for the valve sizes 19, 21, 23, 25, and 27, as 1.49 ± 0.32 cm 2 , 1.67 ± 0.40 cm 2 , 1.92 ± 0.38 cm 2 , 2.01 ± 0.42 cm 2 , and 2.13 ± 0.36 cm 2 , respectively .…”
Section: Introductionmentioning
confidence: 99%
“…Relative to stented valves, such valves offer the advantage of combining a non‐obstructive effective orifice area (EOA) with a flexible aortic root that is thought to be essential for natural leaflet stress distribution, thereby limiting valve degeneration and failure . Depending on prosthesis size, the EOA increases two‐ to threefold after FS implantation and has been reported (mean ± standard deviation [SD]) for the valve sizes 19, 21, 23, 25, and 27, as 1.49 ± 0.32 cm 2 , 1.67 ± 0.40 cm 2 , 1.92 ± 0.38 cm 2 , 2.01 ± 0.42 cm 2 , and 2.13 ± 0.36 cm 2 , respectively .…”
Section: Introductionmentioning
confidence: 99%
“…The design of this prosthesis closely resembles that of the Freedom Solo (Sorin Group) stentless prosthesis that was associated with a higher incidence of SVD at 5 years. 3 However, in this case, the patient's age and history of chronic kidney failure are 2 major risk factors that could explain the early SVD observed. 4 Thus, this report of early Perceval degeneration should be taken with caution.…”
mentioning
confidence: 75%
“…Evidence for the longevity of the Freedom SOLO valve is mixed with reported 10 year freedom of SVD ranging from 92% to as low as 70%. 62,66,67 As such, the current evidence suggests that the longevity of the FS salve is inferior to that of commonly used stented valves, particularly that of the Edwards Perimount.…”
Section: Stented Valvesmentioning
confidence: 99%