The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) on-board blackbody calibration system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
5
3

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…The IR radiation in these two bands is then focused on the LWIR and SMWIR focal plane arrays (FPAs). A flip-in mirror can be inserted into the optical path between M2 and M3 to allow the FPAs to view one of two internal blackbodies designed by the University of Wisconsin-Madison Space Science and Engineering Center 3,4 . A cold shutter at 60 K can be moved into the optical path in front of the Lyot stop to block all incoming radiation to make measurements of the detector dark offset levels.…”
Section: Introductionmentioning
confidence: 99%
“…The IR radiation in these two bands is then focused on the LWIR and SMWIR focal plane arrays (FPAs). A flip-in mirror can be inserted into the optical path between M2 and M3 to allow the FPAs to view one of two internal blackbodies designed by the University of Wisconsin-Madison Space Science and Engineering Center 3,4 . A cold shutter at 60 K can be moved into the optical path in front of the Lyot stop to block all incoming radiation to make measurements of the detector dark offset levels.…”
Section: Introductionmentioning
confidence: 99%
“…The blackbody calibration contribution budget allocation is < 0.5K and the engineering best estimates are <0.35K (LW) and <0.20K (SMW). The uncertainty estimates of the UW-SSEC blackbodies are described in much greater detail in 9 . The uncertainty estimates in the calibrated radiance are obtained through a perturbation analysis of Eq.…”
Section: Gifts Radiometric Calibrationmentioning
confidence: 99%
“…The main advantage of this approach is that the IR beam is much smaller after the telescope so that a true high emissivity cavity design can be used for the blackbodies while keeping the volume, weight, and power requirements to a minimum. The successful design of these blackbodies for the GIFTS sensor is described in 9 . The high absolute accuracy of the onboard reference blackbodies compensates for the additional uncertainty from degradation of the telescope optics over time.…”
Section: Introductionmentioning
confidence: 99%
“…The main purpose of the blackbody design is to provide an isothermal cavity with a very accurate emissivity 3 . Table 1 presents the specification and requirements for the blackbody.…”
Section: Requirements For the Blackbody And Emissivity Monitormentioning
confidence: 99%