2019
DOI: 10.1016/j.nima.2018.11.115
|View full text |Cite
|
Sign up to set email alerts
|

The GRIFFIN facility for Decay-Spectroscopy studies at TRIUMF-ISAC

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
33
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 31 publications
(33 citation statements)
references
References 59 publications
0
33
0
Order By: Relevance
“…A pure beam of 4×10 5 pps 46 K was delivered and implanted into Mylar tape at the center of the GRIF-FIN array. The array was operated with 15 high-purity germanium (HPGe) clover γ-ray detectors [19] (with a HPGe-to-source distance of 11 cm), and was coupled to PACES [17,20], an array of 5 lithium-drifted silicon detectors, operated at liquid-nitrogen temperature, for the detection of conversion electrons placed in the upstream position, and SCEPTAR [17,21], an array of 10 plastic scintillators for β-particle tagging, mounted in the downstream position. A sphere of 20 mm thick Delrin plastic absorber was placed around the vacuum chamber to stop energetic β particles from reaching the HPGe detectors.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…A pure beam of 4×10 5 pps 46 K was delivered and implanted into Mylar tape at the center of the GRIF-FIN array. The array was operated with 15 high-purity germanium (HPGe) clover γ-ray detectors [19] (with a HPGe-to-source distance of 11 cm), and was coupled to PACES [17,20], an array of 5 lithium-drifted silicon detectors, operated at liquid-nitrogen temperature, for the detection of conversion electrons placed in the upstream position, and SCEPTAR [17,21], an array of 10 plastic scintillators for β-particle tagging, mounted in the downstream position. A sphere of 20 mm thick Delrin plastic absorber was placed around the vacuum chamber to stop energetic β particles from reaching the HPGe detectors.…”
Section: Methodsmentioning
confidence: 99%
“…The intensities of the observed γ rays were corrected for summing effects as is discussed in Ref. [17]. Several γ rays from the decay of 46 K were observed at energies greater than 3.2 MeV, so it was necessary to include simulated highenergy efficiency data points based on GEANT4 simulations that were scaled and fitted to the source data [23].…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations