2016
DOI: 10.1016/j.supflu.2015.12.007
|View full text |Cite
|
Sign up to set email alerts
|

The group contribution method (GC) versus the critical point-based approach (CP): Predicting thermodynamic properties of weakly- and non-associated oxygenated compounds by GC-PPC-SAFT and CP-PC-SAFT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
35
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 39 publications
(35 citation statements)
references
References 86 publications
0
35
0
Order By: Relevance
“…Although incorporating Eqs. significantly improves its results, it is still impossible to attain the over‐all accuracy in comparison the previously considered compounds . In particular, the model is unable to reproduce the irregular behavior of the auxiliary thermodynamic properties of water at the low temperatures.…”
Section: Theorymentioning
confidence: 99%
See 2 more Smart Citations
“…Although incorporating Eqs. significantly improves its results, it is still impossible to attain the over‐all accuracy in comparison the previously considered compounds . In particular, the model is unable to reproduce the irregular behavior of the auxiliary thermodynamic properties of water at the low temperatures.…”
Section: Theorymentioning
confidence: 99%
“…7-9 significantly improves its results, it is still impossible to attain the over-all accuracy in comparison the previously considered compounds. [31][32][33][34][35][36][37][38] In particular, the model is unable to reproduce the irregular behavior of the auxiliary thermodynamic properties of water at the low temperatures. Figure 1 depicts the results for densities, sound velocities and heat capacities in wide range of conditions up to 1273 K and 10,000 bar.…”
Section: Theorymentioning
confidence: 99%
See 1 more Smart Citation
“…Development of CP‐PC‐SAFT and its implementations to various systems have been described in great details in the previous studies . Therefore the current discussion is restricted to the mean features of this model and its major differences from sPC‐SAFT …”
Section: Theorymentioning
confidence: 99%
“…15 Nevertheless, it should be emphasized again that, as stated by the authors, the used Cp data may have significant uncertainties, thus a precise comparison of models may be difficult. 22,30 In order to describe the properties of ionic liquids, a generalized version of SAFT + Cubic were developed and used by Polishuk. 27 With the parameters only obtained by two density data, very impressive performance of the model can be observed, and the values of AAD for all investigated properties are lower than 3.1%.…”
Section: Other Eosmentioning
confidence: 99%