2016
DOI: 10.1016/j.enpol.2016.01.021
|View full text |Cite
|
Sign up to set email alerts
|

The impact of building orientation and discount rates on a Portuguese reference building refurbishment decision

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 36 publications
0
11
0
Order By: Relevance
“…It emerges that, especially for some studies in the climate zones Cfa (Italy [12,66]) and Csa (Italy and Portugal, [26,55,74,79]), the cost-optimal energy performance level is very close to zero for both building typologies, demonstrating the possible economic feasibility of nearly zero-energy buildings. However, for other studies in the same climatic zones, the reached cost-optimal energy performance levels are much higher (up to 125 kWh/m 2 ).…”
Section: Global Cost Values and Gapsmentioning
confidence: 98%
“…It emerges that, especially for some studies in the climate zones Cfa (Italy [12,66]) and Csa (Italy and Portugal, [26,55,74,79]), the cost-optimal energy performance level is very close to zero for both building typologies, demonstrating the possible economic feasibility of nearly zero-energy buildings. However, for other studies in the same climatic zones, the reached cost-optimal energy performance levels are much higher (up to 125 kWh/m 2 ).…”
Section: Global Cost Values and Gapsmentioning
confidence: 98%
“…They applied this method to Italian hotels in order to identify building materials that can support national energy and tourism policies. Brandão De Vasconcelos et al [31] also developed reference buildings to make informed decisions on refurbishing buildings from technological as well as economic perspectives. They considered the incorporation of building orientation and discount rates in determining appropriate solutions for refurbishment.…”
Section: Purpose and Application Of Reference Buildingsmentioning
confidence: 99%
“…(2) Natural lighting: Through an in-depth analysis of the sun's altitude, the amount of daylight, etc., many researchers have conducted various studies on how to determine the optimal orientation of a building and on designing the atrium from the perspective of introducing the natural light system for nZEB implementation (refer to Table 2) [16][17][18][19][20][21][22][23][24][25][26][27][28]. First, there are various studies related to determination of the optimal orientation of a building for reducing the building energy demand [16][17][18][19][20]. Abanda and Byer (2016) assessed the impact of the building orientation on building energy consumption using building information modeling according to the following three-step process: (i) building design through the Revit software program; (ii) conversion to a numerical value based on Green Building Studio, one of the leading energy simulation programs; and (iii) analysis of the effect of building orientations on the annual energy usage of a building.…”
Section: Part A-1: Passive Sustainable Designmentioning
confidence: 99%
“…As a result of the analysis of the annual energy consumption according to the seven building shapes, it was determined that the H shape of the building in the Texas climate zone had the highest energy consumption among all the shapes studied [11,15]. (2) Natural lighting: Through an in-depth analysis of the sun's altitude, the amount of daylight, etc., many researchers have conducted various studies on how to determine the optimal orientation of a building and on designing the atrium from the perspective of introducing the natural light system for nZEB implementation (refer to Table 2) [16][17][18][19][20][21][22][23][24][25][26][27][28]. First, there are various studies related to determination of the optimal orientation of a building for reducing the building energy demand [16][17][18][19][20].…”
Section: Part A-1: Passive Sustainable Designmentioning
confidence: 99%