2012
DOI: 10.1149/2.068301jes
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of Experimental Factors on Oxygen Semi-Permeation Measurements

Abstract: International audienceMany recent studies have focused on the development of perovskite membranes with high oxygen semi-permeation performance. However, the usual experimental setups used to measure oxygen semi-permeation values may lead to significant errors in the actual performance of the membrane materials. In this paper, special attention is paid to the experimental conditions and the associated impacts on oxygen semi-permeation measurements collected from the membrane. Furthermore, the experimental setup… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
26
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 27 publications
(27 citation statements)
references
References 44 publications
1
26
0
Order By: Relevance
“…The oxygen semi-permeation and oxygen activities at the membrane surface are measured using a custom built apparatus described in previous studies [24,25] and shown in Fig. 1.…”
Section: Oxygen Surface Exchange and Semi-permeation Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…The oxygen semi-permeation and oxygen activities at the membrane surface are measured using a custom built apparatus described in previous studies [24,25] and shown in Fig. 1.…”
Section: Oxygen Surface Exchange and Semi-permeation Measurementsmentioning
confidence: 99%
“…On the surface membrane, the oxygen surface activities are measured using pure ionic conductor tips (ZrO 2 -8%Y 2 O 3 ) and a metallic electrode in contact with the surface membrane. Then, the oxygen chemical potential through the membrane is evaluated as previously described by Geffroy et al [25].…”
Section: Oxygen Surface Exchange and Semi-permeation Measurementsmentioning
confidence: 99%
“…3), described in previous studies [10,11]. The oxygenpermeation measurement was performed on two membrane samples for each membrane material to ensure reproducibility.…”
Section: Oxygen Semi-permeation Measurementsmentioning
confidence: 99%
“…Their oxygen permeation properties have already been characterized by Reichmann [32,33]. Furthermore, the chemical expansion of La 0.8 Sr 0.2 Fe 0.7 Ga 0.3 O 3−␦ have been extensively studied by Valentin [34] and its Young modulus have been partly characterized by a high temperature ultrasonic pulse echo technique (350 kHz) [35] and by C-ring on tubular part at R.T. [36].…”
Section: Characterization Of Miecsmentioning
confidence: 99%
“…The manufacturing process is extensively detailed in [32][33]. The final relative density of the disks is higher than 95%, the diameter is 25 ± 1 mm and the thickness is 1 ± 0.1 mm.…”
Section: Characterization Of Miecsmentioning