2000
DOI: 10.1118/1.599000
|View full text |Cite
|
Sign up to set email alerts
|

The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy

Abstract: The purpose of this work is to examine the potential impact of the frequency and amplitude of fluctuations ("complexity") in intensity distributions on intensity-modulated radiotherapy (IMRT) dose distributions. The intensity-modulated beams are efficiently delivered using a multileaf collimator (MLC). Radiation may be delivered through a continuous (dynamic mode) or discrete (step-and-shoot) sequence of windows formed by the leaves. Algorithms and software that convert optimized intensity distributions into l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
128
1

Year Published

2007
2007
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 135 publications
(130 citation statements)
references
References 13 publications
1
128
1
Order By: Relevance
“…The beamlet intensity restrictions, smoothing procedures, direct aperture optimization, etc., were proposed by many authors for reducing the beam complexity on treatment planning and delivery for complex intensity patterns while maintaining the dosimetric quality. [18][19][20][21][22][23][24] The change in the inherent segment sequencing parameter of minimum segment width has the positive effect of reducing the MUs needed for delivering very high dose of uncomplicated intensity patterns. Also, a large decrease in plan modulation not only improves delivery efficiency, but also potentially decreases planning and quality assurance time or difficulty.…”
Section: Discussionmentioning
confidence: 99%
“…The beamlet intensity restrictions, smoothing procedures, direct aperture optimization, etc., were proposed by many authors for reducing the beam complexity on treatment planning and delivery for complex intensity patterns while maintaining the dosimetric quality. [18][19][20][21][22][23][24] The change in the inherent segment sequencing parameter of minimum segment width has the positive effect of reducing the MUs needed for delivering very high dose of uncomplicated intensity patterns. Also, a large decrease in plan modulation not only improves delivery efficiency, but also potentially decreases planning and quality assurance time or difficulty.…”
Section: Discussionmentioning
confidence: 99%
“…The term “beam complexity,” first introduced by Mohan et al, (9) is characterized by the frequency and amplitude variations of the beam. Webb (10) proposed the modulation index (MI) by measuring variations of photon fluence between neighboring pixels.…”
Section: Introductionmentioning
confidence: 99%
“…A complex plan requires a large number of MUs 23. In our investigation, the number of MUs required at a collimator angle of 0° was higher than that required with all other tested collimator angles.…”
Section: Discussionmentioning
confidence: 51%