2021
DOI: 10.3390/cells10040953
|View full text |Cite
|
Sign up to set email alerts
|

The Impact of Preprocessing Methods for a Successful Prostate Cell Lines Discrimination Using Partial Least Squares Regression and Discriminant Analysis Based on Fourier Transform Infrared Imaging

Abstract: Fourier transform infrared spectroscopy (FT-IR) is widely used in the analysis of the chemical composition of biological materials and has the potential to reveal new aspects of the molecular basis of diseases, including different types of cancer. The potential of FT-IR in cancer research lies in its capability of monitoring the biochemical status of cells, which undergo malignant transformation and further examination of spectral features that differentiate normal and cancerous ones using proper mathematical … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 53 publications
0
3
0
Order By: Relevance
“…As background, a sample-free spectrum was collected before each sample was recorded and then subtracted automatically from the sample spectra prior to further analysis. Every sample was recorded in triplicate using three new aliquots of powder, resulting in an average spectra from these triplicates (Oberreuter et al, 2002;Piermaria et al, 2011;Lee et al, 2017;Innes et al, 2019;Liberda et al, 2021). Between every measurement the ATR crystal plate was cleaned with ethanol (96%) and dried to ensure a clean crystal surface (Goḿez-Ordoñez and Rupeŕez, 2011).…”
Section: Atr-ftir Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation
“…As background, a sample-free spectrum was collected before each sample was recorded and then subtracted automatically from the sample spectra prior to further analysis. Every sample was recorded in triplicate using three new aliquots of powder, resulting in an average spectra from these triplicates (Oberreuter et al, 2002;Piermaria et al, 2011;Lee et al, 2017;Innes et al, 2019;Liberda et al, 2021). Between every measurement the ATR crystal plate was cleaned with ethanol (96%) and dried to ensure a clean crystal surface (Goḿez-Ordoñez and Rupeŕez, 2011).…”
Section: Atr-ftir Spectroscopymentioning
confidence: 99%
“…Baseline correction provided for ATR in the Perkin Elmer Spectrum IR software version 10.6.1 was used. Multiplicative signal correction, present in "pls" 2.8-0 package (Mevik and Wehrens, 2007), is used as normalization method, as is also the method of choice in the literature for ATR-FTIR (Lee et al, 2017;Innes et al, 2019;Liberda et al, 2021). The spectral range of 2750-1800 cm −1 is excluded because of the low signal-tonoise ratio in this spectral region caused by the absorbance of the ATR crystal.…”
Section: Pre-processingmentioning
confidence: 99%
“…Many artifacts and normalization issues are data type specific and need to be addressed using dedicated preprocessing and filtering methods. Tailored software solutions have been made available to preprocess clinical data [21], NGS data [49], microarray data [50], different types of metabolomics and proteomics data [18], and cellular and brain imaging data [51][52][53][54]. Although no generic rules and methods exist for all data types, the following considerations apply to most datasets.…”
Section: Tip 4: Choose Adequate Preprocessing and Filtering Approachesmentioning
confidence: 99%