2015
DOI: 10.1016/j.ijepes.2014.08.010
|View full text |Cite
|
Sign up to set email alerts
|

The impact of serial controllable FACTS devices on voltage stability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(12 citation statements)
references
References 14 publications
0
12
0
Order By: Relevance
“…The results show that the voltage stability is improved significantly, but on the other side, it will decrease the efficiency of the power system because in case the inverter absorbs reactive power, the grid in turn provides the amount of reactive power needed by PVPP. Some researchers used extra hardware for reactive power control such as STATCOM 92 and FACTS 93 devices, but these devises not only increase the system cost but also increase the system complexity and affects the stability.…”
Section: Reactive Power Requirementsmentioning
confidence: 99%
“…The results show that the voltage stability is improved significantly, but on the other side, it will decrease the efficiency of the power system because in case the inverter absorbs reactive power, the grid in turn provides the amount of reactive power needed by PVPP. Some researchers used extra hardware for reactive power control such as STATCOM 92 and FACTS 93 devices, but these devises not only increase the system cost but also increase the system complexity and affects the stability.…”
Section: Reactive Power Requirementsmentioning
confidence: 99%
“…Among them, Flexible alternating current transmission systems (FACTS) devices have proved to be very effective and viable in alleviating the problems of electrical transmission systems for voltage controller and transient stability [26][27], security, and reliability in the modern power systems [28][29]. In addition, Distributed Energy Systems [30] has on the centralized supply in terms of cost of the energy delivered to consumers is evaluated.…”
Section: Introductionmentioning
confidence: 99%
“…Ref. [9] explains the impact of parallel and serial FACTS devices on the voltage stability; while the present paper introduces the mathematical background and analyses the impact of the UPFC on voltage stability in the EPS.…”
Section: Introductionmentioning
confidence: 99%
“…Figure 1, adopted from [9,12], illustrates the basic structure of an UPFC which consists of two frequency converters: a parallel transformer (denoted as TRP) with a frequency converter 1 and a serial transformer (denoted as TRS) with a frequency converter 2. The converter 1 and 2 are operated from a common DC link provided by a DC storage capacitor: parallel CP and serial CS condenser battery.…”
Section: Introductionmentioning
confidence: 99%