2020
DOI: 10.1007/s11701-020-01071-w
|View full text |Cite
|
Sign up to set email alerts
|

The impact of the AirSeal® valve-less trocar system in robotic colorectal surgery: a single-surgeon retrospective review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…Whereas in many other countries the knowledge on readmissions for different conditions and populations is continuously increasing (e.g. [15][16][17][18][19][20][21]), comparatively little efforts were dedicated to research on readmissions in Germany, the largest European healthcare system, and information on the usability of claims data is particularly limited. Nonetheless, there are conditions of high economical and clinical importance for Germany, generating a high proportion of hospital admissions: The diagnosis of heart failure, for example, was the most frequent discharge diagnosis in German hospitals in 2016, 2017, and 2018 [22].…”
Section: Introductionmentioning
confidence: 99%
“…Whereas in many other countries the knowledge on readmissions for different conditions and populations is continuously increasing (e.g. [15][16][17][18][19][20][21]), comparatively little efforts were dedicated to research on readmissions in Germany, the largest European healthcare system, and information on the usability of claims data is particularly limited. Nonetheless, there are conditions of high economical and clinical importance for Germany, generating a high proportion of hospital admissions: The diagnosis of heart failure, for example, was the most frequent discharge diagnosis in German hospitals in 2016, 2017, and 2018 [22].…”
Section: Introductionmentioning
confidence: 99%
“…Seal designs, in these ports, employ trap-door valves and silicone seals to achieve and maintain a pneumoperitoneum. 14 Moisture collection and entrapment of debris lead to camera smudging. Seals may be disrupted during instrument exchanges and intra-abdominal gas lost during suctioning of liquid and/or smoke.…”
Section: Portsmentioning
confidence: 99%
“…The AirSeal employs laminar flow and CO 2 recirculation. 14 The AirSeal port is a valve-less trocar with a proximal one-way valve and distal hollow thread cannula. A stable pneumoperitoneum will be maintained as there will be a continuous flow of CO 2 from the proximal (external) to distal (internal) end of the valve inside the peritoneal cavity.…”
Section: Portsmentioning
confidence: 99%
See 2 more Smart Citations