2009
DOI: 10.1302/0301-620x.91b7.21914
|View full text |Cite
|
Sign up to set email alerts
|

The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome

Abstract: Narrow, well-defined radiolucent lines commonly observed at the bone-implant interface of unicompartmental knee replacement tibial components have been referred to as physiological radiolucencies. These should be distinguished from pathological radiolucencies, which are poorly defined, wide and progressive, and associated with loosening and infection. We studied the incidence and clinical significance of tibial radiolucent lines in 161 Oxford unicondylar knee replacements five years after surgery. All the radi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
113
3
3

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 125 publications
(125 citation statements)
references
References 24 publications
6
113
3
3
Order By: Relevance
“…Radiographic assessment of the Oxford 1 implant showed the occurrence of radiolucent lines at the boneimplant interfaces. At 5 years followup, Gulati et al [6] reported a 30% rate of complete and 32% rate of partial radiolucent lines around the tibial component. The lucencies did not correlate to implant failure, pain, or functional scores.…”
Section: Discussionmentioning
confidence: 99%
“…Radiographic assessment of the Oxford 1 implant showed the occurrence of radiolucent lines at the boneimplant interfaces. At 5 years followup, Gulati et al [6] reported a 30% rate of complete and 32% rate of partial radiolucent lines around the tibial component. The lucencies did not correlate to implant failure, pain, or functional scores.…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, the UKA cementing technique is technically demanding, particularly if limited incisions are used and if the bone is sclerotic [7,14]. We believe that aseptic loosening is a substantial reason for revision, but, especially for the Oxford 1 UKA prosthesis (Biomet Inc, Warsaw, IN, USA), radiolucent lines under the tibial tray may be misleading [6], but only in a relatively small number of patients. Even so, it appears that reliable fixation for UKAs remains an unsolved problem [20].…”
Section: Discussionmentioning
confidence: 99%
“…The presence of radiolucent lines was noted on standard AP and lateral radiographs of the knee. The ICC for interrater reliability of assessment of the presence of radiolucent lines after UKA is greater than 0.98 [8]. Progression of medial compartment degenerative disease was defined as progression of the medial compartment to a more severe stage of degeneration according to the International Knee Documentation Committee (IKDC) system [10].…”
Section: Methodsmentioning
confidence: 99%