RESULTSAmong the 108 lesions, 49 were indeterminate on planar scintigraphy, 16 on SPECT, and one each on SPECT-CT and CT. SPECT-CT was superior to both planar scintigraphy (P < 0.001) and SPECT alone (P = 0.014), but not to CT (P = 0.302). CT was superior to planar scintigraphy (P < 0.001) but only slightly superior to SPECT (P = 0.063). SPECT-CT correctly characterized 96% of the indeterminate lesions observed by planar scintigraphy. SPECT-CT had an impact on the clinical management of 60.6% patients compared to planar scintigraphy and 18.1% compared to SPECT. CONCLUSION SPECT-CT is better than planar scintigraphy and SPECT alone, but not CT alone, for characterizing equivocal vertebral lesions that are observed by bone scintigraphy, thus SPECT-CT can have a significant impact on patient management.