1991
DOI: 10.4028/www.scientific.net/msf.79-82.363
|View full text |Cite
|
Sign up to set email alerts
|

The INEL X-Ray Position Sensitive Detector: A Study of D-Spacing Accuracy and Exposure Time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

1993
1993
2007
2007

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 27 publications
(19 citation statements)
references
References 0 publications
1
18
0
Order By: Relevance
“…A cubic spline correction of the angular linearity based upon simple pattern reference compounds such as silicon or quartz is insufficient by far. Indeed, previous studies (Deniard, Evain, Barbet & Brec, 1991) have pointed out that those corrections lead to large positive correlations (62o for a given compound is minimum around the standard reflection 20 values but maximum in between those values). This observation suggested a need for a new standard with a large number (> 50) of nonoverlapping intense peaks over the entire 120 ° 20 range.…”
Section: Linearandatandnmentioning
confidence: 99%
See 2 more Smart Citations
“…A cubic spline correction of the angular linearity based upon simple pattern reference compounds such as silicon or quartz is insufficient by far. Indeed, previous studies (Deniard, Evain, Barbet & Brec, 1991) have pointed out that those corrections lead to large positive correlations (62o for a given compound is minimum around the standard reflection 20 values but maximum in between those values). This observation suggested a need for a new standard with a large number (> 50) of nonoverlapping intense peaks over the entire 120 ° 20 range.…”
Section: Linearandatandnmentioning
confidence: 99%
“…Nevertheless, some problems inherent to the detector architecture (such as its linearity) and to the Debye-Scherrer geometry (such as absorption) needed to be thoroughly tackled. A first preliminary investigation of the d-spacing accuracy and the exposure time has already been reported (Deniard, Evain, Barbet & Brec, 1991). The aim of the present work is to complete those studies and to extend them to the question of intensity accuracy.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The peak-by-peak analyses were performed with the PROLIX program (Deniard, Evain, Barbet & Brec, 1991) using pseudo-Voigt profile functions. Latticeparameter measurements were obtained by least-squares refinement from the d-spacing list with the U-FIT program (Evain, 1992).…”
Section: Data Processingmentioning
confidence: 99%
“…Indeed, the simplicity of the Debye-Scherrer setting is associated with the simultaneous collection of data over a large 20 angular range (120 ° for an INEL CPS 120), good counting statistics or with very short measuring time (Deniard, Evain, Barbet & Brec, 1991;Evain, Deniard, Jouanneaux & Brec, 1993), which is particularly interesting for phase transformations and kinetic studies (Plevert, Auffredic, LouEr & LouEr, 1989;Stfihl & Hanson, 1994;W61fel, 1983).…”
Section: Introductionmentioning
confidence: 99%