2017
DOI: 10.1016/j.avsg.2016.08.011
|View full text |Cite
|
Sign up to set email alerts
|

The Influence of Collagen Impregnation of a Knitted Dacron Patch Used in Carotid Endarterectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 24 publications
0
8
0
1
Order By: Relevance
“…From the autologous great saphenous vein graft to the commonly used prosthetic ePTFE and Dacron graft, each graft has its own merits and drawbacks (Bai et al, 2021c). Various modifications of these prosthetic grafts have been made, like heparin and rapamycin coating (Ambler and Twine, 2018;Baba et al, 2021) and collagen coating (Chou et al, 2017); these modification have contributed to the progress of vascular surgery. Along with the development of material science, new materials need to be tested for their application in vascular surgery.…”
Section: Discussionmentioning
confidence: 99%
“…From the autologous great saphenous vein graft to the commonly used prosthetic ePTFE and Dacron graft, each graft has its own merits and drawbacks (Bai et al, 2021c). Various modifications of these prosthetic grafts have been made, like heparin and rapamycin coating (Ambler and Twine, 2018;Baba et al, 2021) and collagen coating (Chou et al, 2017); these modification have contributed to the progress of vascular surgery. Along with the development of material science, new materials need to be tested for their application in vascular surgery.…”
Section: Discussionmentioning
confidence: 99%
“…В свою очередь, Dacron имеет высокую прочность и устойчивость к избыточному растяжению [9] [18]. Но по результатам, полученным другой научной группой, значимая разница по частоте тромбозов и рестенозов между группами с PTFE и Dacron, покрытого коллагеном, отсутствовала [19].…”
Section: виды сосудистых заплатunclassified
“…Gelatin (denatured collagen), however, has been used to impregnate Dacron vascular grafts used in clinical practice, so as to make the material less permeable. This coating was not associated with increased thrombosis or restenosis (Chou et al, ). When thrombogenicity presents as a problem, the material can be coated with heparin to prevent blood clotting using the same carbodiimide cross‐linking step applied in this study (Lammers, van de Westerlo, Versteeg, van Kuppevelt, & Daamen, ).…”
Section: Introductionmentioning
confidence: 98%