2009
DOI: 10.2341/09-024-l
|View full text |Cite
|
Sign up to set email alerts
|

The Influence of Plastic Light Cure Sheaths on the Hardness of Resin Composite

Abstract: SUMMARYObjective: This study investigated the influence of a disposable light cure sheath on both the surface hardness and hardness at varying thicknesses of resin composite.Methods: A series of resin composite discs (Spectrum) were fabricated with varying depths up to 6 mm. The light curing units used were a standard halogen unit (Elipar Trilight) and an LED unit (Elipar Freelight 2). Recommended curing times from the manufacturer were followed. The disposable light-curing sheath (Cure Sleeve) was used with b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
20
0
1

Year Published

2010
2010
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(26 citation statements)
references
References 16 publications
5
20
0
1
Order By: Relevance
“…[13] The effects of curing distance on the %DC values of composite resins are controversial. [4513] Nevertheless, findings in the present study support the theory that polymerization is affected by curing distance[912] in cases of low irradiance levels, such as those emitted by the ultra LED. Despite its inferior power density performance, restoration quality obtained in this investigation using the ultra LED at a distance of 5 mm was acceptable.…”
Section: Discussionsupporting
confidence: 81%
See 2 more Smart Citations
“…[13] The effects of curing distance on the %DC values of composite resins are controversial. [4513] Nevertheless, findings in the present study support the theory that polymerization is affected by curing distance[912] in cases of low irradiance levels, such as those emitted by the ultra LED. Despite its inferior power density performance, restoration quality obtained in this investigation using the ultra LED at a distance of 5 mm was acceptable.…”
Section: Discussionsupporting
confidence: 81%
“…[7] This may decrease light incidence,[36101112] although we recorded a reduction lower than 4% [Table 1]. Curing light units generally provide the minimum light intensity recommended (280-300 mW/cm 2 ),[9] but it may become insufficient with the use of protective barriers on light output.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“…In this study, the micro-hardness was tested immediately after the light curing procedure because the occlusal adjustment, finishing and polishing of the composite resin restorations are usually performed just after light curing the composite resin in clinical situations. Stress created by these procedures can have a detrimental effect on the tooth-restoration interface, such as the premature breakdown of the restoration at the margin 2,22,24 .…”
Section: Discussionmentioning
confidence: 99%
“…Disposable barriers are convenient, non-invasive, and prevent contact between the oral tissues and the light guide. These types of barriers also eliminate the risk of damaging the light guide during autoclaving or disinfection 10,19,22,27 . Among various infection control barriers, the plastic wrap has the least effect on the LCU power density 19,27 .…”
Section: Introductionmentioning
confidence: 99%