2020
DOI: 10.1016/j.energy.2020.117661
|View full text |Cite
|
Sign up to set email alerts
|

The influence of plate corrugations geometry scale factor on performance of plate heat exchanger as condenser of vapour from its mixture with noncondensing gas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 42 publications
0
3
0
Order By: Relevance
“…These correlations can also be used for modelling heat transfer in single-phase flows in commercially produced PHEs by accounting for pressure losses in ports and distribution zones on commercial plates, as discussed in the paper [39]. These correlations were employed in the mathematical modelling of steam condensation from steam-air mixture in three models of the PHE main corrugated field, with the same corrugation angle to the main flow direction 60 • and different corrugations heights 5.0, 7.5 and 10.0 mm [40]. The mathematical model is presented by the system of ordinary differential equations, which is solved by dividing the PHE channel into small-sized segments along its length.…”
Section: The Accuracy Of Heat Transfer Correlations For Phementioning
confidence: 99%
“…These correlations can also be used for modelling heat transfer in single-phase flows in commercially produced PHEs by accounting for pressure losses in ports and distribution zones on commercial plates, as discussed in the paper [39]. These correlations were employed in the mathematical modelling of steam condensation from steam-air mixture in three models of the PHE main corrugated field, with the same corrugation angle to the main flow direction 60 • and different corrugations heights 5.0, 7.5 and 10.0 mm [40]. The mathematical model is presented by the system of ordinary differential equations, which is solved by dividing the PHE channel into small-sized segments along its length.…”
Section: The Accuracy Of Heat Transfer Correlations For Phementioning
confidence: 99%
“…It allows having a bigger cross-section area of channels to decrease pressure drop of heat exchanging stream, that is important for gaseous streams and condensing duty applications. The calculations of steam-air condensation in this PHE were made using the mathematical model presented in paper by Kapustenko et al (2020) with heat and mass transfer coefficients determined according to Arsenyeva et al (2014). The results are presented in Table 2 with the purchasing price in € estimated by Equation (Arsenyeva et al 2016):…”
Section: Case Studymentioning
confidence: 99%
“…PHEs have low fouling tendencies (Crittenden et al 2015). Some PHE types can be used as surface condensers of pure vapour (Arsenyeva et al 2011), of multicomponent vapours mixtures (Tovazhnyansky et al 2004) and of vapour from its mixture with non-condensing gas (Kapustenko et al 2020). This paper is implementing the Process Integration method (Klemeš et al 2018) to find an efficient solution for utilisation of waste sensible and latent heat from exhaust gases with the use of recuperative heat exchangers.…”
Section: Introductionmentioning
confidence: 99%