The influence of printing angle on color and translucency of 3D printed resins for dental restorations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
26
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(27 citation statements)
references
References 36 publications
1
26
0
Order By: Relevance
“…52 However, when non-ideal backgrounds are used, such as the color of the backings in color difference determinations, the RTP is necessary. 20 In our study, translucency calculations were performed as recommended by previous studies. 20,52 According to our study, the highest RTP 00 values were observed the combination of O with GC group.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…52 However, when non-ideal backgrounds are used, such as the color of the backings in color difference determinations, the RTP is necessary. 20 In our study, translucency calculations were performed as recommended by previous studies. 20,52 According to our study, the highest RTP 00 values were observed the combination of O with GC group.…”
Section: Discussionmentioning
confidence: 99%
“…The RTP 00 values were calculated using the CIEDE2000 color formula, as follows 20,21,52 : italicRTP00=[LBLWkLSL2+CBCWkCSC2+HBHWkHSH2goodbreak+2pxRTCBCWkCSCHBHWkHSHtrue]1/2 Subscript B in this formula refers to the color parameter obtained on a black background, while subscript W refers to the color parameter obtained on a white background. The other terms within the formula have been previously stated in detail 20,21 . The relative translucency parameter difference (ΔRTP 00 ) was calculated (before aging–after aging).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The materials evaluated in this study are included in Table 1 along with a description of the clinical uses and composition as provided by the respective manufacturers. [27][28][29][30][31] A light-cured resin composite, milled resin composite, and lithium disilicate milled ceramic were chosen as reference materials as they were expected to have mechanical properties near the 3D-printed resins included in this study. All 3Dprinted resin materials were printed in a vat digital light processing (DLP) printer (Pro 55, SprintRay, Los Angeles, CA).…”
Section: Methodsmentioning
confidence: 99%
“…Shorter 3-point bend flexural strength specimens tend to have higher flexural strength values as there is a lower probability that a critical flaw will be present in a shorter span. In order to compare the values obtained in this study to those of the manufacturers of the 3D-printed resins (>50 MPa C&B MFH, 150 ± 25 MPa Ceramic Crown, 147 MPa OnX),29,30 it would be necessary to know the exact specimen dimension and testing apparatus used by their manufacturers.…”