1996
DOI: 10.1016/0584-8539(95)01655-4
|View full text |Cite
|
Sign up to set email alerts
|

The infrared spectra of complexes with planar dithiooxamides Part VIII. The Au(III) complexes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…20 The Raman spectrum in the low frequency region shows a strong peak at 156 cm Ϫ1 which is assigned to the ν 1 symmetrical stretch of the IBr 2 Ϫ unit and two peaks (mw) at 238 and 225 cm Ϫ1 which are likely to be related to the Au-Br vibrations. 21 In order to evaluate the effectiveness of IBr-and I 2 -adducts in THF solutions compared with the commercial I Ϫ /I 2 aqueous mixtures currently under use for gold dissolution in the etching procedure of microelectronic devices, experiments on gold wires and Si/SiO 2 /Ti/Au thin layers (thickness 300 µm/0.5 µm/15 nm/200 nm) have been performed. Wires of the same length and thickness have been dipped into equimolar solutions (c = 5.0 × 10 Ϫ3 mol dm Ϫ3 ) of the three reagents, then removed, dried and weighed every 10 minutes as shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…20 The Raman spectrum in the low frequency region shows a strong peak at 156 cm Ϫ1 which is assigned to the ν 1 symmetrical stretch of the IBr 2 Ϫ unit and two peaks (mw) at 238 and 225 cm Ϫ1 which are likely to be related to the Au-Br vibrations. 21 In order to evaluate the effectiveness of IBr-and I 2 -adducts in THF solutions compared with the commercial I Ϫ /I 2 aqueous mixtures currently under use for gold dissolution in the etching procedure of microelectronic devices, experiments on gold wires and Si/SiO 2 /Ti/Au thin layers (thickness 300 µm/0.5 µm/15 nm/200 nm) have been performed. Wires of the same length and thickness have been dipped into equimolar solutions (c = 5.0 × 10 Ϫ3 mol dm Ϫ3 ) of the three reagents, then removed, dried and weighed every 10 minutes as shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…[10] The IR bands appearing at 3280 and 1575 cm -1 in the spectrum of dto due to n(NH 2 )and d(NH 2 ), respectively, [11] were found to be located at almost the same frequencies in the corresponding mixed-ligand complexes. Such a shift strongly suggests that the donor atoms in the mixed-ligand complexes have to be the sulfur atoms.…”
Section: Resultsmentioning
confidence: 89%
“…In fact, sulfur donation should be accompanied by a shift to lower frequencies of ν(CϭS) and simultaneously to higher frequencies of ν(CN). [17] Conflicting literature assignments of ν(CϭS)…”
Section: [Hg(me 2 Dazdt)i 2 ]mentioning
confidence: 97%