2007
DOI: 10.1302/0301-620x.89b4.18055
|View full text |Cite
|
Sign up to set email alerts
|

The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip

Abstract: Finite element analysis was used to examine the initial stability after hip resurfacing and the effect of the procedure on the contact mechanics at the articulating surfaces. Models were created with the components positioned anatomically and loaded physiologically through major muscle forces. Total micromovement of less than 10 mum was predicted for the press-fit acetabular components models, much below the 50 mum limit required to encourage osseointegration. Relatively high compressive acetabular and contact… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
45
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 49 publications
(47 citation statements)
references
References 61 publications
2
45
0
Order By: Relevance
“…FE using commercial software has been extensively developed for contact mechanics of artificial joints 25, 26, 27, 28, 29, 30. Scifert et al29 developed a contact model to study factors that can influence hip dislocation; Elkin et al30, 31, 32 extended the model to investigate the effect of subluxation and impingement for MoM bearings and fracture for CoC implants; Mak et al18, 24 calculated contact stress for edge loading due to microsepartion in CoC hip joints; Sariali et al33 also carried out similar predictions for CoC bearings.…”
Section: Introductionmentioning
confidence: 99%
“…FE using commercial software has been extensively developed for contact mechanics of artificial joints 25, 26, 27, 28, 29, 30. Scifert et al29 developed a contact model to study factors that can influence hip dislocation; Elkin et al30, 31, 32 extended the model to investigate the effect of subluxation and impingement for MoM bearings and fracture for CoC implants; Mak et al18, 24 calculated contact stress for edge loading due to microsepartion in CoC hip joints; Sariali et al33 also carried out similar predictions for CoC bearings.…”
Section: Introductionmentioning
confidence: 99%
“…However, there are still instances where simplified representations of the bone properties are implemented, e.g. FE simulations of the pelvis where only two materials are used to represent the cortical and cancellous bone (Zivkovic et al, 2010;Udofia et al, 2007). Models using idealised material properties may capture gross differences, but are unlikely to capture subtle variations and localised effects.…”
Section: Development Of a Representative Model With Appropriate Loadmentioning
confidence: 99%
“…Bone ingrowth/ ongrowth will occur if the micromotions are less than 40-50 μm and fibrous tissue formation will occur if the micromotions are in excess of 150 μm (Pilliar et al, 1986). FE has been extensively to analysis the primary stability of femoral stems (Tensi et al, 1989;Rohlmann et al, 1988; (Udofia et al, 2007;Spears et al, 2001;Janssen et al, 2010;Ries et al, 1997;Spears et al, 1999Spears et al, , 2000Ong et al, 2006;Bellini et al, 2007;Amirouche et al, 2008;Hothi et al, 2011Hothi et al, , 2012 and the tibial component of knee replacement Chong et al, 2010;Kelly et al, 2013;Taylor et al, 1998) since Rohlmann et al, 1988 first explored primary stability. A number of assumptions have become accepted and routinely implemented.…”
Section: Simulation Of the Initial Mechanical Environment Of The Bonementioning
confidence: 99%
See 2 more Smart Citations