The Integrity of ACSR Full Tension Splice Connector at Higher Operation Temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 4 publications
1
4
0
Order By: Relevance
“…The rapid decrease of compressive force in the conductor section at the early stage of thermal cycling (from 20°C to 150°C) will lead to a relatively sharp temperature increase in this temperature range and above before reaching a quasi-steady state. This is consistent with the observation from the thermal cycling temperature profile experiment [1]. Different trends in compressive force from thermal cycling simulation are observed between the heat-up and the cooldown cycles for the core-grip section.…”
Section: B Fem Thermal Cycling Simulationsupporting
confidence: 91%
See 3 more Smart Citations
“…The rapid decrease of compressive force in the conductor section at the early stage of thermal cycling (from 20°C to 150°C) will lead to a relatively sharp temperature increase in this temperature range and above before reaching a quasi-steady state. This is consistent with the observation from the thermal cycling temperature profile experiment [1]. Different trends in compressive force from thermal cycling simulation are observed between the heat-up and the cooldown cycles for the core-grip section.…”
Section: B Fem Thermal Cycling Simulationsupporting
confidence: 91%
“…In collaboration with the Electrical Power Research Institute (EPRI) a series of experiments were carried out to determine the temperature profiles within the connector fitting of an ACSR Drake conductor system during thermal cycling. Measurements were obtained for conductors with both SSC and TSC connectors [1].…”
Section: Temperature Profiles and Thermo-mechanical Characterizationmentioning
confidence: 99%
See 2 more Smart Citations
“…The consequence of temperature rise is the primary root cause of failure in such system. This work explained the myth of increasing failure frequency of conductor-connector system in recent years due to increase in the power demand, which won a 2009 R&D 100 Award [26][27]. There is striking similarity between this earlier work and that of surveillance capsule regarding the gap density in the tubing system.…”
Section: Issue Associated With Hfir Surveillance Capsule Temperaturementioning