1992
DOI: 10.1016/0009-2509(92)80256-c
|View full text |Cite
|
Sign up to set email alerts
|

The interaction between temperature and flow in wall-cooled catalytic fixed-bed reactors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

1995
1995
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 7 publications
1
10
0
Order By: Relevance
“…This conclusion is consistent with Vortmeyer et al's [23] finding that 'for packed beds under typical industrial conditions, the effect of varying fluid properties on the velocity field can be neglected'. Ð R 0 rU z, r ð Þψ z, r ð Þdr, may be expressed as follows (from this point on, = sign will be used instead of ≈ ):…”
Section: The Factorization Modelsupporting
confidence: 92%
“…This conclusion is consistent with Vortmeyer et al's [23] finding that 'for packed beds under typical industrial conditions, the effect of varying fluid properties on the velocity field can be neglected'. Ð R 0 rU z, r ð Þψ z, r ð Þdr, may be expressed as follows (from this point on, = sign will be used instead of ≈ ):…”
Section: The Factorization Modelsupporting
confidence: 92%
“…Moreover, the hot spot occurs in the tube center. This is a common trend in fixed-bed reactors where exothermic reactions take place. , …”
Section: Resultsmentioning
confidence: 99%
“…This is a common trend in fixed-bed reactors where exothermic reactions take place. 5,29 The results plotted in Figures 6−8 were obtained after 49, 125, and 51 s of computation time, respectively. The longer time for Figure 7 was due to the insertion of the inert layers, which drastically changes the equations' gradient and therefore forces the solver ode15s to decrease the integration step to comply with the predefined tolerances.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…In particular, the influence of bed temperature inhomogeneities on cooling air flow distribution, of which there are only a few studies. Through numerical modelling of heated gas flow into a bed, several older studies identified the reduction of air flow through higher temperatures bed regions ( Stanek and Szekely, 1973 ; Stanek and Vychodil, 1987 ; Vortmeyer et al, 1992 ; Wonchala and Wynnyckyj, 1987 ). More recently, Davenne et al (2018) highlighted how the presence of a small, near-inlet, cool zone in a heated bed can substantially impact thermocline uniformity during cooling.…”
Section: Introductionmentioning
confidence: 99%