The Intrapulmonary Percussive Ventilator and Flutter Device Compared to Standard Chest Physiotherapy in Patients wit Cystic Fibrosis

Abstract: Stasis of viscid secretions in cystic fibrosis (CF) leads to chronic infection, inflammation, and lung destruction. Chest physiotherapy (CPT) has been used for many years to assist in the removal of these secretions. However, the need for independently administered CPT exists, particularly for adolescents and the older CF patient. Two devices, the intrapulmonary percussive ventilator (IPV) and the Flutter device (Flutter) have been promoted for this purpose. This study compares these devices to standard, manua… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
65
0
4

Year Published

2000
2000
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(69 citation statements)
references
References 14 publications
0
65
0
4
Order By: Relevance
“…IPV may be delivered via a face mask, a mouthpiece, an endotracheal tube, or a tracheostomy. Recent reports have suggested that IPV facilitates airway clearance and improves homogeneity of ventilation in patients with cystic fibrosis, [1][2][3][4][5] in patients with neuromuscular disorders with retention of mucus, 6,7 in patients with atelectasis, 8 -10 in burned patients with inhalation injury, [11][12][13] and in patients with COPD. 14 -17 Despite potential benefits related to the use of IPV therapy, the impact of setting parameters such as the ratio of inspiratory to expiratory time, the pressure, and the frequency on the mechanical effects produced by IPV devices is totally unknown.…”
Section: Introductionmentioning
confidence: 99%
“…IPV may be delivered via a face mask, a mouthpiece, an endotracheal tube, or a tracheostomy. Recent reports have suggested that IPV facilitates airway clearance and improves homogeneity of ventilation in patients with cystic fibrosis, [1][2][3][4][5] in patients with neuromuscular disorders with retention of mucus, 6,7 in patients with atelectasis, 8 -10 in burned patients with inhalation injury, [11][12][13] and in patients with COPD. 14 -17 Despite potential benefits related to the use of IPV therapy, the impact of setting parameters such as the ratio of inspiratory to expiratory time, the pressure, and the frequency on the mechanical effects produced by IPV devices is totally unknown.…”
Section: Introductionmentioning
confidence: 99%
“…Flow interruption occurred at a frequency of 4–6 Hz [15, 18]. The IPV therapy was delivered with the same 10 ml of isotonic saline solution (0.9% NaCl).…”
Section: Methodsmentioning
confidence: 99%
“…IPV therapy combines internal thoracic percussion with aerosol inhalation. Intrapulmonary percussion is achieved by delivery of rapid small bursts of air along with a side stream of room air and nebulized solution via a unique sliding venturi: the Phasitron [1, 11, 15, 18]. The percussive ventilator device (IPV-2, Percussionaire, Sandpoint, Idaho, USA) was operated by respiratory physiotherapists, adjusting frequency and operating pressure within the above-mentioned ranges for each patient.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Three forms of therapy are provided during IPV: percussive oscillatory vibrations to loosen retained secretions, highdensity aerosol delivery to hydrate viscous mucous plugs, and positive expiratory pressure (PEP) to recruit alveolar lung units. IPV has been compared with other airway clearance therapies in CF and other disease groups (Natale 1994;Homnick 1995;Newhouse 1998;Scherer et al 1998;Toussaint 2003).…”
Section: Intrapulmonary Percussive Vibration (Ipv)mentioning
confidence: 99%