The investigation of magnetic flux dynamics in the bulk HTS with the levitation techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

1999
1999
2008
2008

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(20 citation statements)
references
References 10 publications
0
20
0
Order By: Relevance
“…Measuring the parameters of forced oscillations of a PM one can obtain information about structure and electromagnetic properties of explored HTS samples. Figure 3 represents a basic system [24][25][26], which has been used with granular [27][28][29][30][31][32] and composite [30,32] YBCO and BSCCO ceramics, and, in a slight modification, with the meltprocessed YBCO quasi-single crystals [11,[32][33][34][35][36]. Here, the forced oscillations of the permanent magnet with mass m, magnetic moment , and diameter d, which levitates on the distance of x 0 over the surface of the HTS sample, have been induced by the AC coil, and their amplitude has been measured by the microscope with 5 m accuracy.…”
Section: Resonance Oscillation Techniquementioning
confidence: 99%
See 4 more Smart Citations
“…Measuring the parameters of forced oscillations of a PM one can obtain information about structure and electromagnetic properties of explored HTS samples. Figure 3 represents a basic system [24][25][26], which has been used with granular [27][28][29][30][31][32] and composite [30,32] YBCO and BSCCO ceramics, and, in a slight modification, with the meltprocessed YBCO quasi-single crystals [11,[32][33][34][35][36]. Here, the forced oscillations of the permanent magnet with mass m, magnetic moment , and diameter d, which levitates on the distance of x 0 over the surface of the HTS sample, have been induced by the AC coil, and their amplitude has been measured by the microscope with 5 m accuracy.…”
Section: Resonance Oscillation Techniquementioning
confidence: 99%
“…In [33][34][35] we have shown that the approach of ideally hard superconductor is very useful to describe the elastic properties of levitation systems with the melttextured HTS and as a first approximation to calculate the AC losses. The idea of the approach is to use the surface shielding currents which screens the sample from the penetration of the magnetic field variation (in respect to its initial, frozen distribution over the surface) to calculate the magnetic field distribution outside the superconductor and to obtain from this the elastic properties of the PM-HTS system.…”