2016
DOI: 10.1515/oere-2016-0017
|View full text |Cite
|
Sign up to set email alerts
|

The laboratory investigation of the innovative sensor for torsional effects in engineering structures’ monitoring

Abstract: The main objective of this work is to characterize the performance of an interferometric

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
12
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
3
2
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 19 publications
0
12
0
Order By: Relevance
“…This was made on the base of the Earth rotation measurement regards procedure in detail described in our previous paper [18]. Several experimental tests were carried out to confirm FOSREMs' parameters and reliability including experimental uncertainties calculation based on the registration of the rotational component of the Earth at different frequency bandpass [19], recording strong rotation motion with a new set-up using earthquake simulation [10] and other. As an example, in Figure 4 Because determined parameters fulfill all requirements described for rotational seismology [10], that can be concluded, so FOSREM seems to be appropriate for registration of rotational events associated with rotational seismology.…”
Section: Results Of Laboratory Investigationmentioning
confidence: 99%
See 1 more Smart Citation
“…This was made on the base of the Earth rotation measurement regards procedure in detail described in our previous paper [18]. Several experimental tests were carried out to confirm FOSREMs' parameters and reliability including experimental uncertainties calculation based on the registration of the rotational component of the Earth at different frequency bandpass [19], recording strong rotation motion with a new set-up using earthquake simulation [10] and other. As an example, in Figure 4 Because determined parameters fulfill all requirements described for rotational seismology [10], that can be concluded, so FOSREM seems to be appropriate for registration of rotational events associated with rotational seismology.…”
Section: Results Of Laboratory Investigationmentioning
confidence: 99%
“…Example of a laboratory test of FOSREM-2: (a) temperature stability for the cooling and heating cycle[19], (b) recording rotational speed with increasing angular velocity up to 0.9 rad/s. Finally, regarding the investigation of the sensitivity of the system, as well as their drift, the Allan variance analysis (AV), have been performed[20,21].Figure 5 presents the result of these analyses for FOSREM-1 and -2.…”
mentioning
confidence: 99%
“…Figure 10 shows FOSREM, which was previously described in detail [101]. This device consists of two parts: optical and electronic.…”
Section: Fosrem As a System For Seismological As Well As Engineerimentioning
confidence: 99%
“…The electronic unit calculates and records rotational data through the use of open-loop synchronous detection in a digital form using a 32-bit DSP. This involves specific electronic solutions using signal processing to directly determine the component of rotation according to a previously developed approach [102] using the following formula [101]: normalΩ=Soarctanfalse[Seufalse(tfalse)false]=Soarctanfalse[Se(A1ω/A2ω)false] where S e , S o are the electronic and optical constants of the system, and A 1ω and A 2ω are the first and second amplitudes of the harmonic output signal [ u (t)].…”
Section: Fosrem As a System For Seismological As Well As Engineerimentioning
confidence: 99%
See 1 more Smart Citation