1961
DOI: 10.1016/0095-8522(61)90028-9
|View full text |Cite
|
Sign up to set email alerts
|

The measurement of dynamic surface tensions of solutions of slowly diffusing molecules by the maximum bubble pressure method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1963
1963
1999
1999

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…The diffusion coefficients for the short-time approximation were obtained according to the following procedure: Arbitrary diffusion coefficients were substituted into the model for the short-time approximation (Eq. [21]) until the predicted dynamic surface tension curve fits the initial decrease of the experimentally measured dynamic surface tension. The range of this initial decrease should not be over 1 or 2 dyn/cm.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The diffusion coefficients for the short-time approximation were obtained according to the following procedure: Arbitrary diffusion coefficients were substituted into the model for the short-time approximation (Eq. [21]) until the predicted dynamic surface tension curve fits the initial decrease of the experimentally measured dynamic surface tension. The range of this initial decrease should not be over 1 or 2 dyn/cm.…”
Section: Resultsmentioning
confidence: 99%
“…The integration term in Eq. [21] is difficult to be integrated analytically and requires using a numerical technique.…”
Section: Short Time Approximation For Dwptmentioning
confidence: 99%
See 1 more Smart Citation
“…Most other workers seem to ignore dynamic ST as a criterion of purity even when studying effective methods of purification for ST measurements. Thus Czichocki et al 4 emphasize multiple recrystallization until ST reaches a constant value though this is still below that obtained by many other workers. Rosen3 introduced the very simple and quite effective purification by passage through a short column of C18-covered silica but his ST and cmc results also are lower than could be anticipated.…”
Section: Introductionmentioning
confidence: 99%
“…Figure4. Typical measurement of the surface tension showing the acceptance criterion and the extrapolation to 1 s. 5.48 mM sodium dodecyl sulfate at 25 °C.…”
mentioning
confidence: 99%