2019
DOI: 10.1007/s00414-019-02104-2
|View full text |Cite
|
Sign up to set email alerts
|

The micro-CT evaluation of enamel-cement thickness, abrasion, and mineral density in teeth in the postmortem interval (PMI): new parameters for the determination of PMI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
17
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(20 citation statements)
references
References 23 publications
2
17
0
1
Order By: Relevance
“…In order to analyze the ROI of the whole specimen, the optimal grey value range was determined in the histogram. After the segmentation of the image, the software itself performed the analysis of micro morphometric parameters in an automatic way [43]. The morphometric variables relevant to our study calculated by CTAn software are listed in Table 1 [44,45].…”
Section: Micro-ct Imaging Analysismentioning
confidence: 99%
“…In order to analyze the ROI of the whole specimen, the optimal grey value range was determined in the histogram. After the segmentation of the image, the software itself performed the analysis of micro morphometric parameters in an automatic way [43]. The morphometric variables relevant to our study calculated by CTAn software are listed in Table 1 [44,45].…”
Section: Micro-ct Imaging Analysismentioning
confidence: 99%
“…In particular, in cases of skeletal remains, the PMI becomes very difficult to estimate because soft tissues decrease substantially or completely. Many researchers have focused on the development of novel methods, including infrared (IR)/Raman microscopic imaging techniques [1,2], inductively coupled plasma optical emission spectroscopy (ICP-OES) [3], or microcomputed tomography (µCT) [4,5]. In addition, combinations of techniques have been reported, such as the combined use of different physicochemical methods [6], luminol and microscopic techniques to screen bones before the use of radiocarbon dating [7], ultraviolet (UV)-induced fluorescence and 490 nm induced fluorescence [8], and µCT, mid-infrared microscopic imaging, and energy-dispersive X-ray mapping [9].…”
Section: Introductionmentioning
confidence: 99%
“…We also utilized micro-CT to assess changes in the volume of enamel surfaces at different stages of the experiment. Micro-CT is a non-destructive method of investigating enamel surface changes that provides three-dimensional (3D) high-definition images and has been used by various researchers to study volumetric changes in enamel [ 38 , 39 ]. In an earlier micro-CT study, Farooq et al reported a significant increase in enamel surface volume when they were immersed in a mixture of F-BG toothpaste and AS as compared with Novamin TM and AS mixture [ 35 ].…”
Section: Discussionmentioning
confidence: 99%