2015
DOI: 10.1016/j.nima.2014.09.070
|View full text |Cite
|
Sign up to set email alerts
|

The muon system of the Daya Bay Reactor antineutrino experiment

Abstract: The Daya Bay experiment consists of functionally identical antineutrino detectors immersed in pools of ultrapure water in three well-separated underground experimental halls near two nuclear reactor complexes. These pools serve both as shields against natural, low-energy radiation, and as water Cherenkov detectors that efficiently detect cosmic muons using arrays of photomultiplier tubes. Each pool is covered by a plane of resistive plate chambers as an additional means of detecting muons. Design, construction… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
44
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 55 publications
(45 citation statements)
references
References 36 publications
1
44
0
Order By: Relevance
“…This reflector consists of two layers of DuPont Tyvek 1082D bonded together by a layer of polyethylene. The reflectivity of this material has been measured to be greater than 96% in air and 99% in water, for light of 300-800 nm in wavelength [42].…”
Section: Tyvek Reflectormentioning
confidence: 93%
See 1 more Smart Citation
“…This reflector consists of two layers of DuPont Tyvek 1082D bonded together by a layer of polyethylene. The reflectivity of this material has been measured to be greater than 96% in air and 99% in water, for light of 300-800 nm in wavelength [42].…”
Section: Tyvek Reflectormentioning
confidence: 93%
“…The inner surfaces of the WCV, including the outer surfaces of the LSV, are covered with a layer of a Tyvek-based reflector supplied by the Daya Bay collaboration [42]. This reflector consists of two layers of DuPont Tyvek 1082D bonded together by a layer of polyethylene.…”
Section: Tyvek Reflectormentioning
confidence: 99%
“…See Ref. [21] for a detailed description of the muon system. Each AD is shielded from natural radioactive background and cosmogenic neutrons by at least 2.5 m of water in every direction.…”
Section: B Muon Detectorsmentioning
confidence: 99%
“…More details on the experimental setup are contained in Refs. [49][50][51][52]. The studies in this paper are based on data acquired in the 6-AD period when there were two ADs in EH1, one AD in EH2 and 3 ADs in EH3, with the addition of the 8-AD period from October 2012 to November 2013, a total of 621 days.…”
Section: Sensitivity Of Daya Bay Experiments To Neutrino Wave Packetmentioning