1966
DOI: 10.1088/0026-1394/2/4/004
|View full text |Cite
|
Sign up to set email alerts
|

The NBS Photoelectric Pyrometer and its Use in realizing the International Practical Temperature Scale above 1063 °C

Abstract: apportera un gain appreciable de pr&&ion, en &tendant qu,elle soit a son tour autre mBthode par exemple le comptage des franges d'inter-f6rence d'un laser, m6thode pour laquelle notre inter-

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

1967
1967
2017
2017

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…Null Method-Lee [29], in establishing the NBS pyrometric te mpe rature scale, used Erminy's method with three strip filament lamps to calibrate a fourth lamp at 14 c urre nts , so the radiances we re in the proportion 0.007812 : 0.015625 : 0.03125 : 0.0625 : 0.125 : 0.25 : 0.5: 0.67 : 1.0: 1.5 : 2.0: 3.0: 4.0 : 6.0. Using 1= P (Tr), where P (Tr) is a power fun ction of Tr , he found seven coefficie nts to fit the 14 radiance te mperatures Tr correspondin g to the 14 c urre nts.…”
Section: Measurement Of Radiant Fluxes To Testmentioning
confidence: 99%
See 1 more Smart Citation
“…Null Method-Lee [29], in establishing the NBS pyrometric te mpe rature scale, used Erminy's method with three strip filament lamps to calibrate a fourth lamp at 14 c urre nts , so the radiances we re in the proportion 0.007812 : 0.015625 : 0.03125 : 0.0625 : 0.125 : 0.25 : 0.5: 0.67 : 1.0: 1.5 : 2.0: 3.0: 4.0 : 6.0. Using 1= P (Tr), where P (Tr) is a power fun ction of Tr , he found seven coefficie nts to fit the 14 radiance te mperatures Tr correspondin g to the 14 c urre nts.…”
Section: Measurement Of Radiant Fluxes To Testmentioning
confidence: 99%
“…It tak es seco nd s for the lamp to sta bilize at eac h te mperature, but there may be some circumstan ces whe re this me thod should be used. The paper by Lee [29] describes the be haviour of strip filam e nt lamps. Vacuum lamps are more stable than gas filled lamps, provided th e temperature is kept low.…”
Section: Measurement Of Radiant Fluxes To Testmentioning
confidence: 99%
“…The photoelectric pyrometer is not a new innovation in temperature measurement, but only recently has it come of age as a precision piece of equipment. Since descriptions of this type of device are given elsewhere [11,12] , only pertinent details will be outlined here. Basically, the automatic pyrom· e ter operates on th e same general principle as the well-known visual optical pyrometer with a photo· tube performing the same function as the eye.…”
Section: 2mentioning
confidence: 99%
“…(4) where R" is the spectral responsivity of the instrument and includes the spectral transmittance of the wavelength-limiting element (e.g., interference filter or monochromator), the spectral transmittance of all other optical elements, and the spectral responsivity of the detector. A determination of R" allows a calculation of T from eqs (2 and 4).…”
Section: Basic Theorymentioning
confidence: 99%
“…Photoelectric Pyrometer [4]. A new version of this instrument is under development, which will employ interference filters (1 nm bandpass) and refractive optics.…”
Section: Gas-filled Lampsmentioning
confidence: 99%