1985
DOI: 10.1117/12.967917
|View full text |Cite
|
Sign up to set email alerts
|

The New Streak Image Tube PIF-01

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…However, LI-602 dissector provides limited temporal resolution of not better than 20 ps, which is at least one order of magnitude less than what is required for modern accelerator diagnostics. In order to overcome this limitation, we decided to use, for SR diagnostics, streak image tubes of PIF-01/S1 type, which were developed and have been continuously manufactured at the Photoelectronics Department of A. M. Prokhorov General Physics Institute since the eighties [7]. The experimentally proved limited temporal resolution of such tubes approaches 1±0.2 ps in a single streak mode at 2•10 10 cm/s streak speed and 3 kV/mm electric field strength near the photocathode surface, when femtosecond laser pulses illuminate the tube-input photocathode at 800 and 911 nm wavelength [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…However, LI-602 dissector provides limited temporal resolution of not better than 20 ps, which is at least one order of magnitude less than what is required for modern accelerator diagnostics. In order to overcome this limitation, we decided to use, for SR diagnostics, streak image tubes of PIF-01/S1 type, which were developed and have been continuously manufactured at the Photoelectronics Department of A. M. Prokhorov General Physics Institute since the eighties [7]. The experimentally proved limited temporal resolution of such tubes approaches 1±0.2 ps in a single streak mode at 2•10 10 cm/s streak speed and 3 kV/mm electric field strength near the photocathode surface, when femtosecond laser pulses illuminate the tube-input photocathode at 800 and 911 nm wavelength [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…The dissector is highly sensitive to phase oscillations of beam. We have compared the measurements of the bunch length with the dissector and with the streak camera PS-1/S1 [12], figure 9, which was temporary added to the optical diagnostics.…”
Section: Measurement Of Longitudinal Beam Size With Dissector and Str...mentioning
confidence: 99%
“…The image section of LI-602 dissector consists of a photocathode, electron lens, deflection plates and slit aperture. The electronic optics of PIF-01/S1 streak tube [4] is more complicated. The tube originally was computed, optimized, manufactured and tested for single-shot, streak operation with temporal resolution better than one picosecond [7][8][9].…”
Section: Introductionmentioning
confidence: 99%