2009
DOI: 10.4048/jbc.2009.12.2.100
|View full text |Cite
|
Sign up to set email alerts
|

The Number of Removed Lymph Nodes for an Acceptable False Negative Rate in Sentinel Lymph Node Biopsy for Breast Cancer

Abstract: Purpose: This study was performed to find the adequate number of removed lymph nodes to achieve an acceptable false-negative rate when performing sentinel lymph node biopsy for breast cancer. Methods: A total of 179 sentinel node biopsies combined with conventional axillary lymph node dissection for breast cancer were performed between November 2003 and June 2007. Results: The overall identification rate of sentinel lymph node and the false negative rate of the biopsy were 95.0% and 8.1%, respectively. Yet the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…1 [18,[21][22][23]. Accoding to previous studies [24][25][26][27], the likelihood of a false-negative SLN nding was signi cantly decreased, when SLNs detection number reaches 3, the FNR can reached an acceptable level of less than 5%, the relationship between SLNs removed and FNR was shown in Fig. 2.…”
Section: Discussionmentioning
confidence: 50%
“…1 [18,[21][22][23]. Accoding to previous studies [24][25][26][27], the likelihood of a false-negative SLN nding was signi cantly decreased, when SLNs detection number reaches 3, the FNR can reached an acceptable level of less than 5%, the relationship between SLNs removed and FNR was shown in Fig. 2.…”
Section: Discussionmentioning
confidence: 50%
“…Actually, the numbers of removed SLNs were informative in predicting metastasis in axillary lymph node. According to previous studies [181920], the increase in the number of removed SLNs would result in enhanced accuracy and decline in false negative rate. Particularly, when SLNs detection number reaches 4, the accuracy rate can be stabilized at 95% and the false negative rate can be controlled below 5%.…”
Section: Discussionmentioning
confidence: 99%
“…The false negative rate can be controlled below 11% and the accuracy rate can be over 94% when the number of SLNs reaches 3. When 4 SLNs were detected, the false negative rate was below 2%, and the accuracy rate was above 98% [181920].…”
Section: Discussionmentioning
confidence: 99%