Comprehensive Chiroptical Spectroscopy 2012
DOI: 10.1002/9781118120392.ch10
|View full text |Cite
|
Sign up to set email alerts
|

The Online Stereochemical Analysis of Chiral Compounds by HPLC‐ECD Coupling in Combination with Quantum‐Chemical Calculations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 77 publications
0
11
0
Order By: Relevance
“…The calculated ECD spectra were compared with the experimental ones by using SpecDis . For the calculation of the curves, a UV correction of −18 nm in combination with a spectral bandwidth σ of 0.20 eV was used.…”
Section: Methodsmentioning
confidence: 99%
“…The calculated ECD spectra were compared with the experimental ones by using SpecDis . For the calculation of the curves, a UV correction of −18 nm in combination with a spectral bandwidth σ of 0.20 eV was used.…”
Section: Methodsmentioning
confidence: 99%
“…For example, ECD is not appropriate to elucidate the absolute configuration of molecules without a chromophore and is, in this respect, a little more limited than VCD or ROA. On the other hand, its advantage lies in the sensitivity of the method and in the possible hyphenation to HPLC so that small quantities or even components of complex mixtures can be analyzed online, by HPLC‐ECD, right from the peak in the chromatogram …”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, its advantage lies in the sensitivity of the method and in the possible hyphenation to HPLC so that small quantities or even components of complex mixtures can be analyzed online, by HPLC-ECD, right from the peak in the chromatogram. 2 There are already several reviews [3][4][5][6][7][8] (even in tutorial style 9 ) that describe how to calculate ECD spectra and which theoretical methods are most suited for certain classes of compounds. [10][11][12][13][14][15] Nevertheless, none of them describes in detail the process of comparing the measured and calculated spectra, and which considerations have to be taken into account to unambiguously determine the absolute configuration of a structure by ECD calculations without bias by subjective or even arbitrary criteria.…”
Section: Introductionmentioning
confidence: 99%
“…In the previous study, the acquisition of the ECD spectra was performed on the pure compounds but in the present case, we decided to turn to on-line detection in order to monitor the sign of the Cotton effect (CE) at 280 nm due to the minor amount of compounds present. This method has already been used for several natural products in the past, and proved highly efficient and sensitive [ 15 , 16 , 17 ].…”
Section: Resultsmentioning
confidence: 99%