1989
DOI: 10.1111/j.1475-4754.1989.tb01007.x
|View full text |Cite
|
Sign up to set email alerts
|

The Oxford Accelerator Mass Spectrometry Facility: Technical Developments in Routine Dating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
82
0

Year Published

1996
1996
2012
2012

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 145 publications
(82 citation statements)
references
References 16 publications
0
82
0
Order By: Relevance
“…Gillespie et al 1984Gillespie et al , 1986Batten et al 1986a,b;Fowler et al 1986;Hedges et al 1989;Law and Hedges 1989;Bronk Ramsey et al 2004a). The development of a range of techniques for the analysis of bone specimens has been documented: for example, the dating of peptides van Klinken et al 1994), amino acids using HPLC (van Klinken and Mook 1990; van Klinken and Hedges 1995), and the use of ninhydrin (van Klinken and Hedges 1995).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Gillespie et al 1984Gillespie et al , 1986Batten et al 1986a,b;Fowler et al 1986;Hedges et al 1989;Law and Hedges 1989;Bronk Ramsey et al 2004a). The development of a range of techniques for the analysis of bone specimens has been documented: for example, the dating of peptides van Klinken et al 1994), amino acids using HPLC (van Klinken and Mook 1990; van Klinken and Hedges 1995), and the use of ninhydrin (van Klinken and Hedges 1995).…”
Section: Introductionmentioning
confidence: 99%
“…Particular attention has been paid to contamination issues (e.g. Gillespie and Hedges 1984;Hedges et al 1989;Hedges and van Klinken 1992; Hedges 1995, 1998) and quality control (e.g. van Klinken 1999;Bronk Ramsey et al 2004a;Brock et al 2007).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Collagen is extracted from bone powder using the continuous flow method described in Law and Hedges (1989). Briefly, bone powder (generally 0.1-0.5 g) is placed into a 9 ml reaction vessel.…”
Section: Routine Bone Collagen Preparation Protocolmentioning
confidence: 99%
“…Samples are measured through the NERC-funded ORADS facility, through English Heritage and Historic Scotland, and on a commercial basis. All dates have been achieved by the methods described in Law and Hedges (1989), Hedges et al (1989;. Determinations with OxA numbers greater than 6293 were measured either as graphite (if sufficiently large) or as CO, (Bronk Ramsey and Hedges 1997).…”
Section: Introductionmentioning
confidence: 99%