2022
DOI: 10.14202/vetworld.2022.1107-1112
|View full text |Cite
|
Sign up to set email alerts
|

The position of ground electrode affects electrocardiographic parameters in horses

Abstract: Background and Aim: Improper attachment of the grounding lead is one of the artifacts and causes difficulty in interpretation of ECG. This study aimed to examine the effects of the position of a ground electrode on electrocardiographic (ECG) parameters in horses. Materials and Methods: Sixteen Arabian horses without any cardiac problems were included in this study. The animals were divided into two groups, the base-apex lead method 1 (BA1 method) and the base-apex lead method 2 (BA2 method) with the repositio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 20 publications
1
4
0
Order By: Relevance
“…Atrial activity may not be optimally recorded using these electrode positions. The other ECG parameters of the modified base apex lead method, identical to previous reports [ 14 , 16 , 17 ], were all normal. Despite the trend of rising QRS duration variation in the modified base apex lead method, the duration proved insignificant for determining ventricular size and, thus, unnecessary for diagnosing equine cardiac hypertrophy.…”
Section: Discussionsupporting
confidence: 79%
See 1 more Smart Citation
“…Atrial activity may not be optimally recorded using these electrode positions. The other ECG parameters of the modified base apex lead method, identical to previous reports [ 14 , 16 , 17 ], were all normal. Despite the trend of rising QRS duration variation in the modified base apex lead method, the duration proved insignificant for determining ventricular size and, thus, unnecessary for diagnosing equine cardiac hypertrophy.…”
Section: Discussionsupporting
confidence: 79%
“…This is due to the widespread Purkinje network extending throughout the ventricular myocardium, resulting in multiple points of depolarization across the myocardium, which is different from that observed in humans and small animals [ 12 ]. Optimal electrode positions for good quality ECG recordings have been extensively researched, decreasing movement artifacts and facilitating effortless interpretation [ 16 19 ]. The QRS complex amplitude and duration are unrelated to ventricular size.…”
Section: Introductionmentioning
confidence: 99%
“…However, to the best of our knowledge, this is the first study describing in detail the electrocardiographic reference values in resting Lusitano horses. In this discussion, we compare our results only with studies where the electrodes’ placement was similar to ours since electrode placement can affect ECG parameters, as previously reported [ 31 ].…”
Section: Discussionmentioning
confidence: 88%
“…For the forelimb, The right atrium (RA) (white) electrode was positioned on the right jugular furrow or in front of right scapula spine and the left atrium (LA) (black) electrode was positioned on 5 th intercostal space, just behind the point of the elbow of the left forelimb. For the hindlimb, the LF (red) electrode was positioned on the loose skin at the left stifle in the region of the patella and the RF (green or grounding) electrode was placed on the skin at the xiphoid as described previously [ 30 ]. Alcohol was applied to improve electrical contact.…”
Section: Methodsmentioning
confidence: 99%