Order By: Relevance
“…The other disadvantage might be that the results in terms of ACH obtained following measurement conducted over a period of time are average values, and therefore do not allow one to draw any conclusions regarding characteristics of specific periods of time during the measurement period (such as night periods or when the building is not occupied). Our results indicated low specific airflow rates that possibly Downloaded by [Florida International University] at 07:13 28 December 2014 compromise IAQ and occupants comfort and, due to the low ventilation rate, potentiate airborne contaminant transmission (Lim et al, 2010;Sun et al, 2011). Kalema and Viot (2013) found that the use of transferred air between rooms created a flexible and energy-efficient ventilation alternative to maintain a low CO 2 concentration in educational buildings in situations where there is a constant air volume ventilation and where the use of the space is changed.…”
Section: Discussionmentioning
confidence: 90%
“…The other disadvantage might be that the results in terms of ACH obtained following measurement conducted over a period of time are average values, and therefore do not allow one to draw any conclusions regarding characteristics of specific periods of time during the measurement period (such as night periods or when the building is not occupied). Our results indicated low specific airflow rates that possibly Downloaded by [Florida International University] at 07:13 28 December 2014 compromise IAQ and occupants comfort and, due to the low ventilation rate, potentiate airborne contaminant transmission (Lim et al, 2010;Sun et al, 2011). Kalema and Viot (2013) found that the use of transferred air between rooms created a flexible and energy-efficient ventilation alternative to maintain a low CO 2 concentration in educational buildings in situations where there is a constant air volume ventilation and where the use of the space is changed.…”
Section: Discussionmentioning
confidence: 90%
“…The two-way airflow through the window turned into one-way inflow, and thus re-entry risk was avoided. Lim et al [20,21] further confirmed the possibility of pollutant transmission from lower floors to upper floors through buoyancy-driven airflow by means of field measurement and numerical analysis in a hospital setting. Considering the variety of indoor pollutants, Gao et al [22] utilized Lagrangian and Eulerian models to simulate particulate (pollutant) transmission between adjacent floors.…”
Section: Introductionmentioning
confidence: 89%
“…An effective ventilation is recognized as a very important factor in the control of infections, for human comfort and also for energy recovery and system reliability solutions in operating theatres and isolation rooms in hospitals (Galson and Guisbond 1995;Li et al 2007;Méndez et al 2008;Dascalaki et al 2009;Lim et al 2010). It has been shown that an efficient heating, ventilation and air-conditioning (HVAC) installations can control the air quality and aseptic conditions, safe and suitable indoor thermal conditions for medical staff and surgeons, and patients (Balaras et al 2007).…”
Section: Introductionmentioning