2004
DOI: 10.1038/sj.eye.6701600
|View full text |Cite
|
Sign up to set email alerts
|

The pressure phosphene tonometer—a clinical evaluation

Abstract: Aims Pressure phosphene tonometry is said to assess intraocular pressure by inducing a pressure phosphene. This study compared the results of this relatively new technique with Goldmann applanation tonometry. Methods A total of 100 patients (196 readings) in a general ophthalmology clinic at Dunedin Hospital who consented to take part in this study were randomised to receive by different examiners either pressure phosphene tonometry by a Proview TM eye pressure monitor (Bausch & Lomb Inc., Tampa, FL, USA) or G… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(22 citation statements)
references
References 4 publications
1
21
0
Order By: Relevance
“…However, PPT had been found to be inconsistent as compared to GAT in normal eyes, 38 as well as in patients with glaucoma 39 . In addition, possibly up to 31% of patients may have difficulties in perceiving the pressure phosphene 40 . PPT has also been found to be accurate and reproducible in a narrow IOP range of 9–25 mmHg 41 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, PPT had been found to be inconsistent as compared to GAT in normal eyes, 38 as well as in patients with glaucoma 39 . In addition, possibly up to 31% of patients may have difficulties in perceiving the pressure phosphene 40 . PPT has also been found to be accurate and reproducible in a narrow IOP range of 9–25 mmHg 41 .…”
Section: Resultsmentioning
confidence: 99%
“…39 In addition, possibly up to 31% of patients may have difficulties in perceiving the pressure phosphene. 40 PPT has also been found to be accurate and reproducible in a narrow IOP range of 9-25 mmHg. 41 It has been argued that the target IOP in current glaucoma management is well below 21 mmHg and within the PPT IOP range.…”
Section: Pressure Phosphene Tonometrymentioning
confidence: 91%
“…6,8,9,10,11 The only previous study of PPPT in children was a comparison to non-contact tonometry by Lievens et al 12 That study reported only 2.2% (two subjects out of 93, age range 4-12 years, mean age 8.5 years) were unable to report a phosphene. A few studies of adults with glaucoma have found much higher rates of patients unable to appreciate pressure phosphenes, 13,14 which may in part be due to extensive glaucomatous ganglion loss precluding appreciation of the phosphenes.…”
Section: Discussionmentioning
confidence: 99%
“…4-12) -and found good correlation with GAT. [145][146][147][148] The Proview could still be useful for diurnal IOP estimations by patients themselves if several validating measurements are made side-by-side with the Goldmann or other accurate transcorneal tonometer. 143,144 Unfortunately, subsequent studies failed to confirm the accuracy of this device.…”
Section: Impact-rebound Tonometermentioning
confidence: 99%