The reliability of the gas-filled 110 – 750 kV circuit breaker units of substations

Abstract: Statistical data on the operating reliability of 110 -750 kV gas-filled circuit breaker units in the substations of the unified national electric power grid are analyzed. The structure of outages and planned downtimes of the elements of the units, namely, the circuit breaker and its actuator, the equipment of the unit (the current and voltage transformers, the disconnectors etc.), buses and secondary circuits, are presented. Proposals for increasing the reliability of distributors are substantiated.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…Функції локалізації аварій на електричних станціях та підстанціях виконують насамперед високовольтні вимикачі, від надійності функціонування яких значною мірою залежить стійкість забезпечення електропостачання споживачів. Частка високовольтних вимикачів у загальній пошкоджуваності електрообладнання на сьогоднішній день складає від 30 до 40 % [5,7].…”
Section: нечітке моделювання комутаційного обладнання для задач оцінк...unclassified
“…Функції локалізації аварій на електричних станціях та підстанціях виконують насамперед високовольтні вимикачі, від надійності функціонування яких значною мірою залежить стійкість забезпечення електропостачання споживачів. Частка високовольтних вимикачів у загальній пошкоджуваності електрообладнання на сьогоднішній день складає від 30 до 40 % [5,7].…”
Section: нечітке моделювання комутаційного обладнання для задач оцінк...unclassified
“…It gives only some hints on how to analyse failure data. Dementyev et al compiled statistics about planned and unplanned outages affecting circuit breakers of different voltages with 3860 circuit-breaker years [30]. Andruşcǎ present statistics about different failure types and which parameters should be monitored [31].…”
Section: A Failure Statistics About Circuit Breakersmentioning
confidence: 99%
“…The improvement of the reliability of high-voltage circuit breakers and the in-depth analysis of failure mechanisms have been difficult issues for domestic and foreign power companies and users, switchgear-manufacturing companies, universities, and other research institutions [4,5]. The results of the three reliability surveys conducted by the SC A3 Working Group of the International Council on Large Electric Systems (CIGRE) on switchgear operating in the global grid show that circuit breaker failures caused by mechanical failures, such as the malfunction and refusal to operate of the operating mechanism, account for more than 70% of the total failure rate [6]. Table 1 shows the results of the State Grid Corporation's research on the failure modes of high-voltage circuit breakers in grid operation in China.…”
Section: Introductionmentioning
confidence: 99%