1991
DOI: 10.1016/0045-6535(91)90168-d
|View full text |Cite
|
Sign up to set email alerts
|

The removal efficiency of dioxin in flue gas of MSW incinerator — Comparison of a fabric filter with an electrostatic precipitator —

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

1994
1994
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 1 publication
0
11
0
Order By: Relevance
“…A number of publications report the operation temperature of the filter (Vogg et al 1989, Mariani et al 1990, Greiner & Stelzner 1991, Hiraoka et al 1991, Ide et al 1994, Ishida et al 1998, Shin & Chang 1999, Stieglitz et al 1999, Giugliano et al 2001, 2002, Everaert & Baeyens 2002. These data are used in Figure 5 to plot the PCDD/F concentrations of ESP ashes as a function of the filter temperature.…”
Section: Filter Ashesmentioning
confidence: 99%
“…A number of publications report the operation temperature of the filter (Vogg et al 1989, Mariani et al 1990, Greiner & Stelzner 1991, Hiraoka et al 1991, Ide et al 1994, Ishida et al 1998, Shin & Chang 1999, Stieglitz et al 1999, Giugliano et al 2001, 2002, Everaert & Baeyens 2002. These data are used in Figure 5 to plot the PCDD/F concentrations of ESP ashes as a function of the filter temperature.…”
Section: Filter Ashesmentioning
confidence: 99%
“…However, Shaub and Tsang showed that PCDDlF formed via such a mechanism is unlikely to survive if temperatures are high enough ('900 "C) (5). The PCDD/F concentration in the flue gas leaving the combustion chamber increases while traversing the post-combustion zone (6,7). This observation suggests that the formation takes place in the post-combustion zone, involving lower temperatures and possibly a catalyzed mechanism.…”
Section: Introductionmentioning
confidence: 99%
“…Among them, process temperature is believed to be the most influential parameter (Hiraoka et al, 1990;Ruokojarvi et al, 1998;Tuppurainen et al, 1998;Buekens and Huang, 1998;Weber and Hagenmaier, 1999;. Temperature in an incineration chamber is recommended to be high enough to destroy unburned hydrocarbon.…”
Section: Control Strategiesmentioning
confidence: 99%
“…Incineration is an efficient and widely used technology for disposal of wastes, such as industrial waste, municipal solid waste (MSW), and hazardous waste (Hiraoka et al, 1990;Chang and Huang, 1996;Chang and Chen, 2000;Giugliano et al, 2002;McKay, 2002;Stanmore, 2002). Unfortunately, trace amounts of highly toxic compounds are also generated.…”
Section: Introductionmentioning
confidence: 99%