Purpose
This study aimed to review our experience with the explantation of infected endovascular aneurysm repair (EVAR) grafts.
Methods
This single-center, retrospective, observational study analyzed the data of 12 consecutive patients who underwent infected aortic stent graft explantation following EVAR between January 1, 2010 and December 31, 2019, of which 11 underwent
in situ
graft reconstruction following graft removal. The presentation symptoms, infection route, original pathology of abdominal aortic aneurysms (AAA), graft materials, and clinical outcomes were analyzed.
Results
Six patients underwent total explantation, whereas 5 underwent removal of only the fabric portions. For
in situ
reconstructions, prosthetic grafts and banked allografts were used in 8 and 3 patients, respectively. Four mechanisms of graft infection were noted in 11 patients: 4 had bacteremia from systemic infections, 3 had persistent infections following EVAR of primary infected AAA, 3 had ascending infections from adjacent abscesses, and 1 had an aneurysm sac erosion resulting in an aortoenteric fistula. No infection-related postoperative complications or reinfections occurred during the mean 65.27-month (standard deviation, ±52.51) follow-up period. One patient died postoperatively because of the rupture of the proximal aortic wall pseudoaneurysm that had occurred during forceful bare stent removal.
Conclusion
Regardless of graft material,
in situ
graft reconstruction is safe for interposition in treating an infected aortic stent graft following EVAR. In our experience, the residual bare stent is no longer a risk factor for reinfection. Therefore, it is important not to injure the proximal aortic wall when removing the bare stent by force.