2022
DOI: 10.3390/app12157845
|View full text |Cite
|
Sign up to set email alerts
|

The Role of a DirectDensity® CT Reconstruction in a Radiotherapy Workflow: A Phantom Study

Abstract: The DirectDensity® CT reconstruction algorithm provides a reconstruction approach independent of the tube voltage, directly reconstructing the CT projection data into CT numbers related to the electron densities of the materials. This work examines the efficacy of DirectDensity® in the treatment planning process with both tissues and metallic materials. CT scans of a Cheese phantom were acquired at 80, 100, 120 and 140 kVp and reconstructed with different algorithms. Calibration curves were built for each kVp … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 16 publications
0
2
0
Order By: Relevance
“…The performance of automatic contouring could be quantitatively evaluated in terms of time and quality by comparing it with manual contouring or other software solutions, following the approach of Bi et al [20] . Demonstrating unambiguous improvement in image quality and minimizing imaging dose can only be achieved through repeated phantom measurements, as it has been consistently demonstrated in previous studies [5] , [15] , [16] . This level of assessment is not feasible with patients.…”
Section: Discussionmentioning
confidence: 84%
See 1 more Smart Citation
“…The performance of automatic contouring could be quantitatively evaluated in terms of time and quality by comparing it with manual contouring or other software solutions, following the approach of Bi et al [20] . Demonstrating unambiguous improvement in image quality and minimizing imaging dose can only be achieved through repeated phantom measurements, as it has been consistently demonstrated in previous studies [5] , [15] , [16] . This level of assessment is not feasible with patients.…”
Section: Discussionmentioning
confidence: 84%
“…Due to variable CT tube voltage with CarekV, Direct Density (DD) provides a reconstruction algorithm for images directly proportional to RED. This energy-independent approach allows for a single calibration curve across all tube voltages, though the calibration process is more intensive [15] , [16] .…”
Section: Methodsmentioning
confidence: 99%