2017
DOI: 10.2217/fca-2017-0037
|View full text |Cite
|
Sign up to set email alerts
|

The Role of Cardiovascular Ultrasound in Diagnosis and Management of Pulmonary Embolism

Abstract: The diagnosis of acute pulmonary embolism (PE) is one of the most important problems in medical emergencies. Commonly accepted criterion for diagnosis of deep venous thrombosis is the lack of vein compressibility assessed by Compression UltraSonography. Echocardiography represents an easily available and reliable imaging technique in the clinical setting of hemodynamic instability and in the direct visualization of thromboembolic masses in the right heart chambers. Moreover, echocardiography is useful for prog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 78 publications
0
1
0
Order By: Relevance
“…Then, the total delay time τ)(x2,z,x can be expressed as [30]: τt)(x2,z,x=zxosθ+xsinθc+)(xx22+z2c The signal at the target point is the result of the delayed superposition of the received signals of all the array elements in the aperture. Then, the relationship between the echo signals RF)(x2,t and τ)(x2,z,x can be expressed as [31] S)(x,z=j=aaRFxj,τxj,z,x For composite Doppler imaging, a parameter θi is introduced here because it needs to emit plane waves in different directions. The final signal of the target point needs to accumulate the RF signals obtained by the multiple angles of the plane wave, and then S)(x,z=ifalse∑j=aaRF)(xj,τ)(xj,z,x In ultrasound blood flow imaging, the estimate of Doppler frequency false(Fsfalse) is dependent on the PRF.…”
Section: Methodsmentioning
confidence: 99%
“…Then, the total delay time τ)(x2,z,x can be expressed as [30]: τt)(x2,z,x=zxosθ+xsinθc+)(xx22+z2c The signal at the target point is the result of the delayed superposition of the received signals of all the array elements in the aperture. Then, the relationship between the echo signals RF)(x2,t and τ)(x2,z,x can be expressed as [31] S)(x,z=j=aaRFxj,τxj,z,x For composite Doppler imaging, a parameter θi is introduced here because it needs to emit plane waves in different directions. The final signal of the target point needs to accumulate the RF signals obtained by the multiple angles of the plane wave, and then S)(x,z=ifalse∑j=aaRF)(xj,τ)(xj,z,x In ultrasound blood flow imaging, the estimate of Doppler frequency false(Fsfalse) is dependent on the PRF.…”
Section: Methodsmentioning
confidence: 99%