2016
DOI: 10.1016/j.nima.2016.06.058
|View full text |Cite
|
Sign up to set email alerts
|

The role of electron scattering from registration detector in the “Troitsk nu-mass” MAC-E type spectrometer

Abstract: There is a proposal to search for a sterile neutrino in a few keV mass range by the "Troitsk nu-mass" facility. In order to estimate sterile neutrino mixing one needs to make precision spectrum measurements well below the endpoint using the existing electrostatic spectrometer with a magnetic adiabatic collimation, or MAC-E filter. The expected signature will be a kink in the electron energy spectrum in tritium beta-decay. In this article we consider the systematic effect of electron backscattering on the detec… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Transmission function deviates from the step function characterizing an ideal spectrometer due to effect described in [5], and stronger effect arises at potentials lower than 14 kV (in the range which we do not employ in the present measurements) due to break up of adiabaticity. We used e-gun calibration results to describe and calibrate spectrometer response function.…”
mentioning
confidence: 71%
See 2 more Smart Citations
“…Transmission function deviates from the step function characterizing an ideal spectrometer due to effect described in [5], and stronger effect arises at potentials lower than 14 kV (in the range which we do not employ in the present measurements) due to break up of adiabaticity. We used e-gun calibration results to describe and calibrate spectrometer response function.…”
mentioning
confidence: 71%
“…1. Simulation of the back scattering processes from the detector with reflection of the scattered particles back to the detector by electrostatic and magnetic mirrors [5], which dominate C o u n t r a t e p e r 2 0 c h a n n e l s A D C ( c h a n n e l s ) E x p e r i m e n t S i m u l a t i o n : i n i t i a l r e g i s t e r e d p i l e u p in this region of amplitudes, qualitatively shows similar exponential shape. The measured slope of this exponent is almost the same for different spectrometer potential or the electron energy.…”
Section: Corrections and Systematicsmentioning
confidence: 99%
See 1 more Smart Citation
“…n 0 is the normalization and cannot be inferred from electrode measurements. Instead, a simulation was performed to determine the amount of backscattered electrons that are not backreflected and get lost in the WGTS depending on their initial energy [31]. n 3 does not show a slope and is described by a single constant c n 3 .…”
Section: Experimental Responsementioning