2003
DOI: 10.1016/s0168-9002(03)01941-7
|View full text |Cite
|
Sign up to set email alerts
|

The RPI multiplicity detector response to γ-ray cascades following neutron capture in and

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…In case of capture cross section measurements, the capture sample can be replaced by a sample containing 10 B. At RPI the incident neutron flux is determined by replacing the capture sample by a 2.54 mm thick, 97.9 wt% enriched 10 B 4 C sample and recording the 478-keV γ-ray in the capture detection system consisting of a 16-segment NaI(Tl) detector [111]. Peakto-background ratios between 180 and 400 from 12 eV up to 600 eV, respectively, are obtained [79].…”
Section: B(nαγ) 7 LImentioning
confidence: 99%
See 1 more Smart Citation
“…In case of capture cross section measurements, the capture sample can be replaced by a sample containing 10 B. At RPI the incident neutron flux is determined by replacing the capture sample by a 2.54 mm thick, 97.9 wt% enriched 10 B 4 C sample and recording the 478-keV γ-ray in the capture detection system consisting of a 16-segment NaI(Tl) detector [111]. Peakto-background ratios between 180 and 400 from 12 eV up to 600 eV, respectively, are obtained [79].…”
Section: B(nαγ) 7 LImentioning
confidence: 99%
“…A system based on 48 NaI(Tl) crystals was used at the Kurchatov Institute by Muradyan et al [179]. A similar system, containing 16 NaI(Tl) crys-tals, is used for capture cross section measurements in the thermal and epi-thermal energy region at the TOFfacility of RPI [79,95,111]. A detection assembly of 16 BGO-crystals is installed at KURRI [38,114].…”
Section: Total Absorptionmentioning
confidence: 99%
“…More recently [9], an algorithm that combined Monte Carlo γ-ray cascades predicted by the nuclear statistical model with a Monte Carlo particle transport code was used to demonstrate that the predicted and measured multiplicity distributions for a multi-element NaI detector were in agreement for 3 − and 4 − resonances in 149 Sm+n. A similar technique was used to demonstrate good agreement between the measured and predicted multiplicity spectra for a multi-element BaF 2 detector [10].…”
Section: Introductionmentioning
confidence: 99%
“…Capture detector relative efficiencies were determined for the Dy isotopes using results from Ref. [3].…”
Section: Data Reductionmentioning
confidence: 99%