The SYNERGY biodegradable polymer everolimus eluting coronary stent: Porcine vascular compatibility and polymer safety study

Abstract: In a swine model, everolimus was released by 90 days and PLGA bioabsorption was complete shortly thereafter. The SYNERGY stent and its biodegradable polymer, even at a 3× safety margin, demonstrated vascular compatibility similar to bare metal stent controls.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
25
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 44 publications
(26 citation statements)
references
References 14 publications
1
25
0
Order By: Relevance
“…Moreover, both release their drug loads prior to full coating absorption, rendering their comparison even more relevant. SYNERGY releases 50 and >95% of its drug load by 28 and 90d, 28 slower than durable coated Cypher SES, while O3FA DES achieves these targets by 5 h and 8d. Moreover, whereas the O3FA DES coating begins to rapidly absorb upon implantation with only 15% remaining at 8d, the PLGA coating is relatively biostable up to 28d and achieves 85% erosion only after 90d.…”
Section: Discussionmentioning
confidence: 98%
See 4 more Smart Citations
“…Moreover, both release their drug loads prior to full coating absorption, rendering their comparison even more relevant. SYNERGY releases 50 and >95% of its drug load by 28 and 90d, 28 slower than durable coated Cypher SES, while O3FA DES achieves these targets by 5 h and 8d. Moreover, whereas the O3FA DES coating begins to rapidly absorb upon implantation with only 15% remaining at 8d, the PLGA coating is relatively biostable up to 28d and achieves 85% erosion only after 90d.…”
Section: Discussionmentioning
confidence: 98%
“…Correspondingly, SYNERGY stents provide a near constant Everolimus concentration in subjacent tissue, 1–2 μ g/g, between 5 and 90d, 28 whereas tissue levels of Corolimus were only detectable up to 56d post O3FA DES implantation. Correspondingly, the published 90d data for the O3FA are non-inferior and perhaps better than SYNERGY under overlap in pig coronary arteries 28 (0.21 ± 0.14 mm vs. 0.46 ± 0.22 neointimal thickness and 29.29 ± 13.72 vs. 46.15 ± 18.03% stenosis. Thus, a comparison of O3FA DES to SYNERGY is supportive of our hypothesis that biocompatibility of O3FA compared favorably to synthetic polymers such as PLGA and (B) that there is an advantage to delivering Sirolimus analog Corolimus at a fast rate compared to Cypher.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations