The second critical capillary number for chemical flooding in low permeability reservoirs: Experimental and numerical investigations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 47 publications
(13 citation statements)
references
References 45 publications
0
13
0
Order By: Relevance
“…Special apparatus (see Figures 4 and 5) designed to measure the dynamic capillary pressure of tight porous media was employed to examine the dynamic effect during the displacement process in the fractured tight column samples. 38 Two important parts of the apparatus are the modified pressure transducers (PTs) and the LCR meter (type TH2810D), respectively. As for the pressure transducers, semipermeable plates and probes are fixed in them, with the probes in contact with the rock sample sides.…”
Section: Apparatusmentioning
confidence: 99%
“…Special apparatus (see Figures 4 and 5) designed to measure the dynamic capillary pressure of tight porous media was employed to examine the dynamic effect during the displacement process in the fractured tight column samples. 38 Two important parts of the apparatus are the modified pressure transducers (PTs) and the LCR meter (type TH2810D), respectively. As for the pressure transducers, semipermeable plates and probes are fixed in them, with the probes in contact with the rock sample sides.…”
Section: Apparatusmentioning
confidence: 99%
“…During the displacement process, the P c – S w relationships are dynamic, and their dependence on the ∂S w / ∂t is regarded as the dynamic effect . This dynamic effect has been intensely discussed in the literature via experiments, analytical studies, and mathematical modeling . Several models have been developed to quantitatively demonstrate the dynamic effect on the P c – S w relationship .…”
Section: Introductionmentioning
confidence: 99%
“…The experimental procedures are the same as our previously published papers (Li et al, , 2017(Li et al, , 2019. The original water and oil saturations were firstly achieved, and the experimental rig was prepared by vacuuming and saturating the semi-permeable plates.…”
Section: Methodsmentioning
confidence: 99%
“…The apparatus (Fig. 2) is specially designed to investigate the dynamic effect in capillary pressure and the fluid flow behavior during the displacement process in low to tight porous media under high pressure and high temperature (Li et al, 2019). The vital units are the pressure measurement unit and the fluid saturation measurement unit.…”