2022
DOI: 10.3390/ijms23116008
|View full text |Cite
|
Sign up to set email alerts
|

The Short-Day Cycle Induces Intestinal Epithelial Purine Metabolism Imbalance and Hepatic Disfunctions in Antibiotic-Mediated Gut Microbiota Perturbation Mice

Abstract: Intestinal microbiota dysbiosis is related to many metabolic diseases in human health. Meanwhile, as an irregular environmental light–dark (LD) cycle, short day (SD) may induce host circadian rhythm disturbances and worsen the risks of gut dysbiosis. Herein, we investigated how LD cycles regulate intestinal metabolism upon the destruction of gut microbes with antibiotic treatments. The growth indices, serum parameters, concentrations of short-chain fatty acids (SCFAs), and relative abundance of intestinal micr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 71 publications
0
3
0
Order By: Relevance
“…Briefly, 100 mg of rumen contents and epithelial tissue samples were first treated with 600 μL of methanol solution. Sample preparation was carried out as we described previously ( 65 ). LC-MS untargeted metabolome analysis was performed using a Vanquish UHPLC system (Thermo Fisher Scientific, Santa Clara, CA) with an Acquity UPLC HSS T3 column (150 mm × 2.1 mm, 1.8 μm; Waters, Milford, MA) at a column temperature of 40°C, a flow rate of 0.25 mL/min, and an injection volume of 2 μL at Panomix Biomedical Tech Co., Ltd. (Suzhou, Jiangsu, China).…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, 100 mg of rumen contents and epithelial tissue samples were first treated with 600 μL of methanol solution. Sample preparation was carried out as we described previously ( 65 ). LC-MS untargeted metabolome analysis was performed using a Vanquish UHPLC system (Thermo Fisher Scientific, Santa Clara, CA) with an Acquity UPLC HSS T3 column (150 mm × 2.1 mm, 1.8 μm; Waters, Milford, MA) at a column temperature of 40°C, a flow rate of 0.25 mL/min, and an injection volume of 2 μL at Panomix Biomedical Tech Co., Ltd. (Suzhou, Jiangsu, China).…”
Section: Methodsmentioning
confidence: 99%
“…Data analysis steps for RNA‐Seq followed a previous study 38 . Briefly, the Fastp software (v0.23.1) 39 was first used to perform quality control (QC) on the raw data and obtain clean data.…”
Section: Methodsmentioning
confidence: 99%
“…Data analysis steps for RNA-Seq followed a previous study. 38 Briefly, the Fastp software (v0.23.1) 39 was first used to perform quality control (QC) on the raw data and obtain clean data. Then, the HISAT2 software (v2.1.0) 40 was used to align the obtained clean data referred to the latest reference genome in mouse (GRCm39).…”
Section: Rna-seq Data Processingmentioning
confidence: 99%